Unit Size
Return Air
Voltage
Controls
Cabinet
Revision Level
Supply Air & Motor Option
TS
1 2
TS = Tranquility
®
20
Single Stage Scroll
(Rotary: Size 006-012)
Model Type
V
3
V = Vertical Upflow
Configuration
L = Left Return
R = Right Return
0 = None
Water Circuit Options
2 = HWG (Coil Only)
6 = HWG (Coil Only) w/Auto Flow Regulator 2.5 GPM/Ton
7 = HWG (Coil Only) w/Auto Flow Regulator 3.0 GPM/Ton
8 = Auto Flow Regulator 2.5 GPM/Ton
9 = Auto Flow Regulator 3.0 GPM/Ton
S
15
S = Standard
Standard
H = Horizontal
D = Vertical Downflow
5 = Secondary Circulating Pump
Option
Supply Configuration
Motor
T
D
B
Top
Down
Back
TSV
TSD
TSH
PSC
PSC
PSC
S
Straight
TSH
PSC
V
TSV
PSC Hi Static
U
TSD
Y
TSH
Z
TSH
Top
Down
Back
Straight
K
TSV
ECM
N
TSD
ECM
P
TSH
ECM
W
TSH
ECM
Top
Down
Back
Straight
PSC Hi Static
PSC Hi Static
PSC Hi Static
Heat Exchanger Options
CXM
DXM
CXM w/LON
DXM w/LON
CXM w/MPC
DXM w/MPC
Control
w/o Disconnect
w/ Disconnect
C
D
L
M
N
P
A
B
E
K
R
S
Standard
ClimaDry
®
Reheat
Non Coated Air Coil
Copper
Cupro-Nickel Copper
Cupro-Nickel
C
E
N
P
A
D
J
F
Motorized Valve
T
S
U
W
G = 208/230/60/1
H = 208/230/60/3
* N/A for Sizes 006-012
E = 265/60/1
N = 575/60/3
F = 460/60/3
AVAILABLE
VOLTAGES
006 - E,G
009 - E,G
012 - E,G
018 - E,G
024 - E,F,G,H
030 - E,F,G,H
036 - E,F,G,H
042 - E,F,G,H,N
048 - E,F,G,H,N
060 - E,F,G,H,N
070 - F,G,H,N
OPTION
1
A
J
K
2
C
L
M
3
E
N
P
1” FILTER
RAIL
RANGE
ULTRA
QUIET
2” FILTER
RAIL
1” FILTER
FRAME
2” FILTER
FRAME
4
G
R
S
NO
YES
NO
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
ClimaDry
®
reheat coil not coated
*Microchannel On Sizes 024-048
A = Current Revision Sizes 006-012
B = Current Revision Sizes 018
C = Current Revision Sizes 024-070
Tin Plated Air Coil /
Microchannel Air Coil*
*
*
*
*
*
*
*
*
Model Nomenclature - General Overview
Note: Above model nomenclature is a general reference. Consult individual engineering guides for detailed information.
ClimaDry
®
II Option Notes:
1. Unit must have DXM control option. 460 volt unit units require a four wire power supply with neutral.
2. ClimaDry
®
II may not be combined with motorized water valve, internal secondary circulating pump, or automatic
fl ow regulator options.
3. Unit minimum entering air temperature while in the dehumidifi cation, cooling, or continuous fan modes is
65ºF DB/55ºF WB
. Operation below this minimum may result in nuisance faults.
4. A thermostat with dehumidifi cation mode or thermostat and separate humidistat/dehumidistat is required for
activation and control of ClimaDry
®
II.
5. Downfl ow and 575 volt units are not eligible for ClimaDry
®
II.