Vertical Air Discharge Condensing Units 26 to 100 HP
Dual Compressor
Additional Standard Features
for Parallel Piped Units
1. Replaceable core liquid line filter drier
2. Replaceable core suction filter
3. Suction accumulator
4. Oil management system
5. Contact Factory for Beacon II
TM
Application
Standard and Optional Features
•
Designed for use with R-404A/507
•
Bitzer compressors with POE oil
•
Thermally protected permanently lubricated ball
bearing condenser fan motors
•
Electrical controls, including compressor contactor
and optional defrost control, are located in easily
accessible control box with a hinged cover
•
Receivers are sized for sufficient pumpdown
capacity with inlet and outlet service valves
•
Cabinet is constructed from prepainted
galvanized steel
•
Convenient access panels for easy servicing to
internal components
•
Suction and discharge vibration eliminators
•
Separate subcooling circuit in condensers for added
capacity and vapor-free liquid
•
Sealed liquid line filter drier and sight glass
•
Service Mate
™
module to assist troubleshooting
•
Floating Tube
™
coil design
•
Prebent copper tubes minimize welded joints on
internal piping
•
Adjustable head pressure control valves
Factory-Installed Options
•
Replaceable core liquid line filter driers with
sight glasses
•
Liquid line solenoid valves
•
Suction filters
•
Replaceable core suction filters
•
Suction accumulators
•
Oil separators with discharge line check valves
•
Air defrost timers
•
Electric defrost kits, including timer, evaporator fan
contactor with fusing, defrost heater contactor(s),
lockout relay and terminal strip
•
Low ambient kits with heated and insulated receiver with
time delay
•
Compressor unloading
•
External discharge line mufflers
•
Phase-loss protection
•
Manual-reset high pressure switches
•
Anti-short cycling timers
•
Compressor circuit breakers
•
Condenser fan cycling (standard on CDDS)
•
Three way heat reclaim valve with mounted check valves
•
Coated condenser coils for protection against corrosion
in harsh environments
•
Beacon II
™
compatible
Nomenclature
C
D
D
000B
L
6
C
Brand
Airflow
Horsepower
Temp. Range
Refrigerant
Voltage
C =
Climate
Control
D -
D = Vertical
DS = Vertical
Beacon
II
™
260B - 26
300B - 30
400B - 40
440B - 44
500B - 50
600B - 60
660B - 66
700B - 70
800B - 80
110B -100
M = Med. Temp.
L = Low Temp.
6 = R-404A,
R-507
C = 208-230/3/60
D = 460/3/60
E = 575/3/60