12
Single
Ver
tic
al A
ir D
ischar
ge C
ondensing Unit
Standard and Optional Features
•
The Floating Tube™ coil design. Refrigerant-carrying copper
tubes do not contact any metal support sheets; instead,
the coil is constructed with expanded anchor tubes that
support the coil construction and do not carry refrigerant.
The coil design eliminates one of the major causes of leaks in
refrigeration systems
•
Limited five-year warranty against condenser tube sheet and
center support leaks
•
Designed for use with R-404A, R-507
•
Prebent copper tubes minimize welded joints on
internal piping
•
All sweat type connections, no flare joints to leak
•
Fixed high pressure switch eliminates capillary tubes
•
Oil safety control
•
Bitzer compressors with POE oil
•
Spring mounted compressor with suction and discharge
vibration eliminators
•
Crankcase heater
•
Thermally protected, permanently lubricated ball bearing
condenser fan motors
•
Separate subcooling circuit in condenser for added capacity
and vapor-free liquid
•
Receivers are sized for sufficient pumpdown capacity with
inlet and outlet service valves
•
Pressure relief valve on receiver
•
Sealed liquid line filter drier and sight glass
•
Electrical controls, including compressor contactor and
optional defrost control, are located in easily accessible
control box with a hinged cover
•
Service Mate
™
module to assist troubleshooting
•
Pumpdown Switch
•
Cabinet is constructed from prepainted galvanized steel
•
Convenient access panels for easy servicing to internal
components
•
Adjustable head pressure control valves
Factory-Installed Options
•
Compressor unloading
•
Replaceable core liquid filter drier
•
Liquid line solenoid valve
•
Suction filter
•
Replaceable core suction filter
•
Suction accumulator
•
Oil separator with discharge line check valve
•
Air defrost timer
•
Electric defrost kits, including timer, evaporator fan contactor
with fusing, defrost heater contactor(s), lockout relay and
terminal strip
•
Fusing for defrost kits
•
Evaporator holdout relays for systems with multiple electric
defrost evaporators
•
Low ambient kit with heated and insulated receiver with
time delay
•
Fused disconnect switch
•
Non-fused disconnect switch
•
Phase-loss protection
•
Manual-reset high pressure switch
•
Anti-short cycle timer
•
Compressor circuit breakers
•
Condenser fan cycling (standard on CDVS)
•
Three-way heat reclaim valve (n/a on CDVS)
•
Coated condenser coils for protection against corrosion in
harsh environments
•
Beacon II
™
compatible
Vertical Air Discharge Condensing Units 13 to 50 HP
Single Compressor
Nomenclature
C
D
V
000B
L
6
C
Brand
Airflow
Horsepower
Temp. Range
Refrigerant
Voltage
C =
Climate
Control
D -
V = Vertical
VS = Vertical Beacon
II
™
130B - 13
150B - 15
200B - 20
220B - 22
250B - 25
300B - 30
330B - 33
350B - 35
400B - 40
500B -50
M = Med. Temp.
L = Low Temp.
6 = R-404A,
R-507
C = 208-230/3/60
D = 460/3/60
E = 575/3/60