Climate Control CCS-22HR4GP Скачать руководство пользователя страница 12

ʎ

ʎ

ʎ

Ĺ

Install front panel

)b*

)c*

ķ

ĸ

Ĺ

Clean and care

Caution

Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock. 

Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock.

Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft

cloth, or a cloth slightly moistened with water or cleanser.)

Clean the front panel (make sure to take it off before cleaning)

Place two supporters of the front panel into the slots, along the

direction of arrowhead to cover and clasp the front panel. As show 

 in Fig.4(a,b)

Fig.4

Clean the air filter (Recommended once every three months)

Note:   If dust is much more around the air conditioner, the air filters should be cleaned

many times. After taking off the filter, don't touch the fin of indoor unit, in order to avoid
hurt your fingers.

 At the slot of surface panel to open an angle, pull the air filter downward

 and take it out, please see the  Fig. 5(a,b).

 To clean the dust adhering to the filters, you can either use a vacuum

 cleaner, or wash them with warm water (the water with the neutral detergent 

 should below 45

), and dry it in the shade.

Reinsert the filters along the direction of arrowhead, and then to cover 

the cover and clasp it.

Take down the air filter

Note: Never use water above 45 

o

C to clean, or it can cause

 deformation or discoloration. Never parch it by fire, or can

 cause a fire or deformation. 

Insert the air filter 

Fig. 5

Clean the air filter

D

E

ķ

ĸ

Take off the front panel

Along the direction of arrowhead to lift up the front panel, 

and after disassembled the displayer, to pull the front panel 
at the both slots of the front panel,then take it off.

Washing

Clean with a soft hairbrush, water and neutral detergent,

then to dry it in the shade.(Note: Before cleaning, please take 

water above 45

ć

to wash the panel, or it could cause 

deformation or discolouration.

off the displayer at first, then clean the front panel, in 
order to prevent the water damage and never use the 

DŽ

&

Содержание CCS-22HR4GP

Страница 1: ...TYPE carefully before operating the unit and keeps it carefully Thank you for choosing our air conditioner for correct operation please read this owner s manual for consultation CCS 22HR4GP 6612990330...

Страница 2: ...5 6 10 15 17 18 20 21 22 12...

Страница 3: ...power cables and control wires If the power cable and signal control wire were damaged change them by professional Power must adopts the special circuit to prevent fire Otherwise it can cause an elec...

Страница 4: ...n cause afire or explosion It can decrease the air conditioning capacity or cause a malfunction It can decrease the air conditioning capacity Please note whether the install ed stand is firm enough or...

Страница 5: ...y for a long time It can cause the health problems Don t use the air conditioner for other purposes such as drying clothes preserving foods etc The power cords of this air conditioner adopt X type con...

Страница 6: ...tdoor temperature is low but high humidity after a long while running frost will form on outdoor unit that will effect the heating effect at this time the auto defrosting function will act the heat ru...

Страница 7: ...ape Window receiver Drainage pipe Power cords Air in Air out Wireless remote control Heat COOL Set TEMP RUN indicator DRY Window receiver Display board Front panel Indoor unit Outdoor unit Manual swit...

Страница 8: ...perature will be changed quickly Thetemperaturesettingrangeis16 30 COOL HEAT COOL button HEAT button At operating pressing this button could enter into the COOL mode directly At operating pressing thi...

Страница 9: ...LOW OFF At AUTO FAN or HEAT modes the BLOW function cannot be set and there is no BLOW displayed Pressing this button enter into SLEEP state or quit the SLEEP state After unit is turned off and cancel...

Страница 10: ...may be not available for some units 4 Press TURBO button can realize the ON and OFF of TURBO function The above operation please refers to Page 8 Page 9 for details Introduction for special functions...

Страница 11: ...ise it can cause the malfunction of the wireless remote control take them out and don t let the leakage liquid damage the wireless remote control The operation should be in its receiving range It shou...

Страница 12: ...ce panel to open an angle pull the air filter downward and take it out please see the Fig 5 a b To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm wat...

Страница 13: ...eck that whether the batteries of air conditioner are changedornot Checkthatwhethertheinstallationstandoftheoutdoor unitisdamagedornot Ifdamaged pleasecontactthedealer Maintain after use Turnmainpower...

Страница 14: ...uthorized maintenance center There s unusual smell blowing from the outlet after operation is started Sound of water flow can be heard during the operation The air conditioner is started when it is ru...

Страница 15: ...t in its receiving range Or obstructed To check the voltage in wireless remote control batteries inside is charged otherwise to replace the Whether the wireless remote control is damaged If water leak...

Страница 16: ...o avoid condensing water be vaporized again restrain temperature rising defrosting there is water flowing out or vapor be produced Indoor unit cannot deliver air If unit is running under the high humi...

Страница 17: ...place where is strong enough to withstand the full weight and vibration of the unit And will not increase the noise Be sure to leave enough space to allow access for routine maintenance The height of...

Страница 18: ...ed to the special earth device the installation work should be operated by the professional The air switch must have the functions of magnetic tripping and heat tripping in order to protect the short...

Страница 19: ...Space to the wall Space to the floor Air outlet side Space to the wall Space to the obstruction Air inlet side Space to the wall Air outlet side Space to the wall Above Above Above Above Above Above I...

Страница 20: ...Protection sleeve pipe Install the water drainage pipe For well draining the drain hose should be placed at a downward slant Do not wrench or bend the drain hose or flood its end by water 2 3 When the...

Страница 21: ...e tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and put them th rough the piping hole As show...

Страница 22: ...outdoor Valve cap JDXJH 9DFXXP SXPS Liquid pipe Gas pipe LJ LJ Chassis Outdoor drain elbow through the drain hose DV SLSH LTXLG SLSH LTXLG YDOYH H DJRQ DV YDOYH Freon charge nuzzle Screwdriver QGRRU...

Страница 23: ...e part Has the unit been connected to a secure earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet...

Страница 24: ...ition As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rei...

Страница 25: ...restricted or unsafe eg high locations g Freight charges including insurance or travelling cost for repairs performed outside the area normally serviced by Advanced Group Australia P L or a repair age...

Отзывы: