2008 Directed Electronics—all rights reserved
2
Shutdown diagnostics
To perform shutdown diagnostics
With the ignition OFF, press and
HOLD
the Valet/Program switch.
Turn the ignition ON and then back OFF while
HOLDING
the Valet/Program
switch.
Release the Valet/Program switch.
Press and release the Valet/Program switch. The LED starts flashing to report
the last shutdown for one minute or until the ignition is turned on, as shown
in the following table:
LED Flashes
Shutdown Mode
1
Runtime expired
2
Over-rev shutdown
3
Low or no RPM
4
Transmitter shutdown (or optional push button)
5
(+) Brake shutdown
6
(-) Hood shutdown
7
Timer mode/Turbo mode/Manual mode error *
8
Neutral safety shutdown
9
Low battery (voltage mode)
10
Alarm triggered **
11
Wait-to-start input timed out
*Timer mode error: Ignition is on or shutdown input is active when activating
timer mode.
Turbo mode error: Turbo mode is programmed off, engine is not on or shutdown
input is active.
Manual mode error: MTS mode not enabled.
** Alarm was triggered during remote start sequence.
1.
2.
3.
4.
Содержание Responder LE 3.3X
Страница 90: ...N5202X 2008 02 ...