![Clifford Responder LE 3.3X Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/clifford/responder-le-3-3x/responder-le-3-3x_installation-manual_2624422057.webp)
©
2008 Directed Electronics—all rights reserved
3. Choose
.
Within 10 seconds, press and release the
Program switch corresponding to the number of the
desired function step listed in the following table.
Once you have selected the function step, press the switch once
more and
hold
it. The LED will flash and the siren will chirp to con-
firm the selected functional step. Do not release the Program switch.
Step
Function
1
Auto Learn Standard Configuration* (default)
The auto learn configuration will automatically setup the remotes button configuration.
Note:
Due to the Supercode protocol, you cannot change the configuration.
2
Delete remotes: This feature will erase all remotes from the memory of the security
system. This is useful in cases when a customer’s remote is lost or stolen.
Note:
: This will not reset the programmed features of the security system or reset the
Virtual Tach setting.
3
Reset Features: This resets features all of the security system to the factory default set-
tings.
Note:
This feature does not delete the remotes from the security system or reset
the Virtual Tach setting.
4
Virtual Tach Reset: Deletes all previously learned values for Virtual Tach, and on the next
remote start sequence the unit will begin virtual tach initialization.
Note:
The “Zap” feature on the Bitwriter will not reset the Virtual tach setting.
4.
Transmit.
While holding the Valet/Program switch, press
the
button on the remote control. The unit will chirp
to confirm that the code has been successfully pro
grammed. It is not possible to teach a remote control but
ton to the system more than once.
5. Release.
Once the code is learned, the Valet/Program
switch can be released.
Содержание Responder LE 3.3X
Страница 90: ...N5202X 2008 02 ...