CHAPTER 3 – INSTALLATION
MOUNTING
The CLiC WD-02.2 Glass Controller must be installed within an appropriate NEMA enclosure. The device can be
mounted (details below) within the enclosure or free standing. The WD-02.2 does not need to be mounted near
the CLiC Glass panel. Both the CLiC Glass powered outputs and the dry contact inputs can be extended up to 100
meters (328 feet).
Mounting Pattern Drawings
POWER
D
O NOT APPLY POWER PRIOR TO COMPLETING ALL WIRING CONNECTIONS AND TERMINATIONS
.
A
LL PROTECTIVE FILMS MUST BE REMOVED PRIOR TO CONNECTING THE WD-02.2 GLASS CONTROLLER
The included power supply (A/C Adapter)
should be connected to the ‘24 VDC
in
’ and ‘Ground’ input terminals on
the WD-02.2. The terminal connector will be pre-attached to the power supply. The CLiC WD-02.2 will be powered
on and begin functioning upon applying power.
Use only the supplied power supply to power the WD-02.2. Do not connect more than one WD-02.2 to a power
supply.
WD-02.2