background image

 

Rev. G

 

CARDINAL CLiC WD-02.2 

GLASS CONTROLLER 

INSTALLATION MANUAL 

  

 

Содержание Cardinal WD-02.2

Страница 1: ...Rev G CARDINAL CLiC WD 02 2 GLASS CONTROLLER INSTALLATION MANUAL ...

Страница 2: ...ce Water and Moisture Do not use the device near water for example near a sink in a wet basement near a swimming pool near an open window in a damp mechanical room etc Object and Liquid Entry Do not allow objects to fall or liquids to be spilled into the enclosure through openings Indoor Use Only The device should be installed and used indoors only Do not use the device outdoors Servicing There ar...

Страница 3: ...ent does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that ...

Страница 4: ...to Users 3 Overview 5 Important Notes 5 Compatability 5 What s In The Box 5 Unpacking and Inspection 6 Controller Layout 7 Mounting 8 Power 8 Wire Connection Terminals 9 Site Wiring and Preparation 10 System Layout Examples 11 Specifications 13 Common Symptoms and Solutions 14 Conctacting Us 15 ...

Страница 5: ...ed in an area where it could get wet Only use the power supply that is included with the WD 02 2 The included power supply is a 100 watt UL listed 1310 power supply with a Class 2 power limited output Using the wrong type of power supply may result in damage Do not disassemble the device Service of the WD 02 2 should be performed by authorized personnel only COMPATABILITY This device is specifical...

Страница 6: ... of the packaging material in case you ever need to ship the unit Thoroughly inspect and make sure the devices are in good condition and there is no visible damage If you have any doubt about the product s integrity please contact your reseller or an authorized support center immediately ...

Страница 7: ...closure NOTE Shielded wire must be used for all connections to the WD 02 2 The shield shall be terminated on the WD 02 2 end of the wire only and shall be connected to either of the Ground terminals as labeled above The shield at the CLiC Glass end and the Switching Device end can be cut where the cable jacket is removed ...

Страница 8: ...28 feet Mounting Pattern Drawings POWER DO NOT APPLY POWER PRIOR TO COMPLETING ALL WIRING CONNECTIONS AND TERMINATIONS ALL PROTECTIVE FILMS MUST BE REMOVED PRIOR TO CONNECTING THE WD 02 2 GLASS CONTROLLER The included power supply A C Adapter should be connected to the 24 VDC in and Ground input terminals on the WD 02 2 The terminal connector will be pre attached to the power supply The CLiC WD 02...

Страница 9: ...ignal output used for driving the CLiC Glass panel Both Glass Out A and Glass Out B must be connected to the CLiC Glass panel Glass Out A and Glass Out B can be connected to either corner of the CLiC Glass panel Shorting the outputs will damage the WD 02 2 and should be avoided NOTE Only connect a single CLiC Glass panel Not to be used with multiple CLiC Glass panels Terminal Glass Out B This is t...

Страница 10: ...THAT THESE DEVICES ARE INSTALLED WITHIN AN AIR EXCHANGE SPACE PLENUM AIRWAY THEY SHALL BE MOUNTED WITHIN AN APPROPRIATE CERTIFIED PLENUM SAFE ENCLOSURE OF MINIMUM SIZE GREATER THAN 273 X 100 X 138MM Wire Type and Connections Shielded two conductor wire must be used for all wire connections on the WD 02 2 Glass Controller This is important to maintain FCC compliance and to minimize the chance for e...

Страница 11: ...ontact Connections The WD 02 2 has been designed to accommodate many installation configurations and scenarios by utilizing a flexible Dry Contact Input Circuit This circuit allows a wide variety of switch devices relays or other automation controllers to provide end user control of the CLiC Glass panel These devices can include but are not limited to Standard light switches NOTE USED FOR LOW VOLT...

Страница 12: ...Page 12 of 15 Rev G Single Channel Multiple Channels Single Switch Multiple Channels Multiple Individual Switches Multiple Channels with Automation and Relay Controls ...

Страница 13: ...priate NEMA enclosure WD 02 2 Dimensions W x H x D without feet 5 99 x 3 03 x 1 24 152 2mm x 77mm x 31 5mm Required Power Supply 24v DC 100 watt UL 1310 Class 2 Included Power Supply Dimensions W x H x D 8 75 x 2 68 x 1 53 222 2mm x 68mm x 38 8mm Weight without included power supply 9 92 oz 0 62 lbs Weight with included power supply 53 44 oz 3 34 lbs Operating Temperatures 50 F to 122 F 10 C to 50...

Страница 14: ... or dry contact device to Glass Controller 3 Verify switch or dry contact device is functioning properly and closing the circuit 4 If a digital multi meter is present verify presence of 24VDC at terminal on Glass Controller 5 See No Power to Glass Controller Below No power at Glass Controller 1 Verify the power supply is plugged into a wall outlet 2 Verify that the wall outlet has power 3 Verify t...

Страница 15: ...egarding your CLiC products please contact our technical support department by email at CLiCsupport cardinalcorp com Please include the following information within your email Your Name Company Name Telephone Number Email address Product models and serial numbers Detailed description of your question or the problems you are experiencing We greatly appreciate your purchase of Cardinal CLiC products...