CLF Conan Скачать руководство пользователя страница 3

Safety Information

The

 

following

 

symbols

 

are

 

used

 

to

 

identify

 

important

 

safety

 

information

 

on

 

the

 

product

 

and

 

in

 

this

 

manual

:

                                          WARNING!
       Read the safety precautions in this section before
        installing, powering, operating or servicing this
                                            product

DANGER!
Safety hazard.
Risk of severe
injury or death.

DANGER!
Hazardous
voltage. Risk of
lethal or severe
electric shock.

WARNING!
Fire hazard.

WARNING!
LED light
emission. Risk of
eye injury.

WARNING!
Burn hazard. Hot
surface. Do not
touch.

WARNING!
Wear protective
eyewear

.

WARNING!
Refer

 

to

 

user

 

manual

.

Warning! Risk Group 3 (high risk) LED product according to EN 62471. Do not look into the beam at a distance 
of less than 8.3 meters from the front surface of the product. Do not view the light output with optical 
instruments or any device that may concentrate the beam.

l

l

Always ground (earth) the fixture electrically.

l

Use only a source of AC power that complies with local building and electrical codes and has both overload and 
ground-fault (earth-fault) protection.

l

Before using the fixture, check that all power distribution equipment and cables are in perfect condition and rated for 
the current requirements of all connected devices.

l

Power input and throughput cables must be rated 20 A minimum, have three conductors 1.5 mm² (16 AWG) minimum 
conductor size and an outer cable diameter of 5 - 15 mm . Cables must be hard usage type (SJT or equivalent) and 
heat-resistant to 90° C minimum.

l

Use only PowerCon cable connectors to connect to power input sockets. Use only PowerCon cable connectors to 
connect to power through put sockets.

l

Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or other component  is 
damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power until repairs   have been 
completed.

This

 

product

 

is

 

for

 

professional

 

use

 

only

It

 

is

 

not

 

for

 

household use

.

This

 

product

 

presents

 

risks

 

of

 

severe

 

injury

 

or

 

death

 

due to fire and burn

 

hazards

electric

 

shock

 

and

 

falls

.

Read this manual before

 

installing

powering

 

or

 

servicing

 

the fixture

follow the

 

safety

 

precautions

 

listed

  

below

 

and

 

observe

 

all

 

warnings in this manual

 

and printed on the fixture

If you

 

have

 

questions

 

about

 

how

 

to

 

operate the

 

fixture

 

safely

please

 

contact

 

your

 

supplier

PROTECTION

 

FROM

 

ELECTRIC

 

SHOCK

Disconnect the fixture from AC power before removing or installing any cover or part  and when not in use.

3

Содержание Conan

Страница 1: ...CLF Conan V 2 11 JULY 2015 C o n a n ...

Страница 2: ...Dimensions All dimensions are in millimeters 2 ...

Страница 3: ...erfect condition and rated for the current requirements of all connected devices l Power input and throughput cables must be rated 20 A minimum have three conductors 1 5 mm 16 AWG minimum conductor size and an outer cable diameter of 5 15 mm Cables must be hard usage type SJT or equivalent and heat resistant to 90 C minimum l Use only PowerCon cable connectors to connect to power input sockets Use...

Страница 4: ...ure in any way not described in this manual l Do not look continuously at LEDs from a distance of less than 8 3 meters from the front surface of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irritation At distances of 8 3 meters and above light output is harmless to the naked eye provided that the eye s ...

Страница 5: ...necting the data link 9 Tips for reliable data transmission 9 Physical installation 10 Fastening the fixture to a flat surface 10 Setup 11 Control panel and menu navigation 11 DMX address setting 11 WDMX control 11 Control mode 12 Restoring factory default settings 12 Operation and effects 13 Effects 13 DMX protocol 14 Standard mode 14 Manual mode 16 Onboard control menus 17 18 Specifications 19 C...

Страница 6: ...achment point Display DMX input DMX output AC mains power throughput AC mains power input Note head fan grill in production models is rotated 90 compared to this illustration G Clamp with Quicklock 875760 Optional 6 Antenna wireless solutions optional ...

Страница 7: ...ters l DMX control Warning Read Safety Information on page 3 before installing powering operating or servicing the fixture Before applying power to the fixture l Carefully review Safety Information starting on page 3 l Check that the local AC mains power source is within the fixture s power voltage and frequency ranges l See Power cables and power plug on page 8 Install a PowerCon power input conn...

Страница 8: ... a building electrical installation if you want to install it permanently or a power plug that is suitable for the local power outlets can be installed on the power cable Warning Check that the voltage range specified on the fixtures serial number label matches the local AC mains power voltage before applying power to the fixture The fixtures accept AC mains power at 100 240 V nominal 50 60 Hz Do ...

Страница 9: ... connect more than ten fixture fixtures in total to AC mains power in one interconnected chain Relaying power to other devices Data link A DMX 512 data link is required in order to control a fixture via DMX The fixture has 3 pin XLR connectors for DMX data input and output The pin out on all connectors is pin 1 shield pin 2 cold and pin 3 hot Or the fixture has 5 pin XLR connectors for DMX data in...

Страница 10: ...he weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or air vents in the base may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment point see Fixture overview on page 6 ...

Страница 11: ...controller For independent control each fixture must be assigned its own control channels The DMX address is configured using the DMX ADDRESS menu in the control panel Press the button UP to switch off Wireless DMX or disconnect with all connected Transmitters Press the button DOWN to set the unit in the ready to connect with all not connected transmitters mode If you press the mode button on the ...

Страница 12: ...ing It gives a virtually instantaneous reaction when you dim from one intensity to another but dimming slowly from one intensity to another may appear slightly uneven l The SMOOTH setting gives smoother dimming during slow changes in intensity but it limits the speed of dimming changes slightly This makes it ideal for slow smooth dimming but a short time lag may be noticeable if you try to dim qui...

Страница 13: ...hanical color wheel and let you snap between 33 different full LEE referenced colors You can also scroll continuously forwards or backwards through the colors or display random colors at variable speed Color wheel priority The color wheel effect channels for the Beam have priority and override any color set on the Beam RGBW channels To use the RGBW and RGB channels you must set the color wheel eff...

Страница 14: ...low Shutter open Strobe 7 burst pulse fast slow Shutter open Strobe 8 random burst pulse fast slow Shutter open Strobe 9 sine wave fast slow Shutter open Strobe 10 burst fast slow Shutter open Beam Dimmer 0 100 intensity Zoom Wide narrow Fixture control settings No function 1 Reset entire fixture No function 2 Fan mode FULL No function 2 Fan mode REGULATED No function 3 Calibrated color output mod...

Страница 15: ...0 Beam Green Green 0 100 Beam Blue Blue 0 100 Beam white white 0 100 Beam CCT No Function CTC 10 000K 2 500K RGBW color mixing enabled Percent 0 1 2 67 68 69 70 78 79 80 81 89 90 91 92 93 94 95 96 97 98 100 0 100 0 100 0 100 0 100 0 07 8 100 DMX Value 0 9 10 174 175 179 180 201 202 207 208 229 230 234 235 239 240 244 245 249 250 255 0 255 0 255 0 255 0 100 0 19 20 255 Standard Note DMX values labe...

Страница 16: ...16 Manual mode Percent 0 100 0 100 0 100 0 100 0 100 DMX Value 0 255 0 255 0 255 0 255 0 255 Manual 1 1 2 3 4 Manual ZOOM Function RED 0 255 GREEN 0 255 BLUE 0 255 WHITE 0 255 Wide narrow ...

Страница 17: ... Factory calibration mode RGBW to white is Factory calibration 10 Auto programs available Select the step 0 20Hz Select strobe frequency transition time of last step to current step 0 step time DIMMER RED GREEN BLUE WHITE ZOOM STROBE FANS Cooling fan speed thermostatically regulated Max cooling fan speed DIMMER MODE Linear dimming curve Square law dimming curve Inverse square law dimming curve S c...

Страница 18: ...brate by DMX control to enter dmx controller calibration channel 4 is set to 245 249 Percent 0 100 0 100 0 100 0 100 0 89 90 95 96 97 98 10 0 99 100 0 100 0 100 0 100 0 100 DMX Value 0 255 0 255 0 255 0 229 230 234 240 244 245 249 250 255 0 254 255 0 255 0 255 0 255 0 255 channel 1 2 3 4 5 6 7 8 9 Function No function No function No function No function 5 come back to DMX mode No function 5 turn o...

Страница 19: ...ak angle Optics Light source Osram Ostar high power long life emitters Control and Programming Control DMX DMX channels 4 10 Setting and addressing Control panel with backlit graphic display Protocol USITT DMX512 A Construction Color Black Housing High strength die casting aluminum Protection rating IP 20 Installation Orientation Any Minimum distance to combustible materials 100 mm from fixture Mi...

Страница 20: ...uto ranging electronic switch mode Power consumption all effects static zero light output 15 W Thermal Cooling Forced air temperature regulated low noise user definable levels Maximum ambient temperature Ta max 40 C Minimum ambient temperature Ta min 5 C Total heat dissipation calculated 10 820 BTU hr 20 ...

Отзывы: