Function

Beem Color

 

wheel

 

effect

No

 

function

 

 

 

Color

 

wheel

 

effect

Open

Color

 

wheel

 

rotation

 

effect

Clockwise

,

 

fast

 

 

slow

Stop

 

(

this

 

will

 

stop

 

wherever

 

the

 

color

 

is

 

at

 

the

 

time

)

Counter

 

-clockwise

,

 

slow

 

 

fast

Open

Random

 

color

Fast
Medium
Slow
Open

Beam Red

Red

 

0

 

 

100

%

Beam Green

Green

 

0

 

 

100

%

Beam Blue

Blue 0 

 

100%

Beam white

white 0 

 

100%

Beam

 

CCT

No Function
CTC 10 000K 

 

2 500K

RGBW color mixing enabled

Percent

0 - 1

2 - 67

68 - 69

70 - 78
79 - 80
81 - 89
90 - 91

92 - 93
94 - 95
96 - 97

98 - 100

0-100

0-100

0-100

0-100

0-07

8-100

DMX Value

0 - 9

10 - 174

175 - 179

180 - 201
202 - 207
208 - 229
230 - 234

235 - 239
240 - 244
245 - 249
250 - 255

0-255

0-255

0-255

0-100

0-19

20-255

Standard   

 

Note: DMX values labeled "No function" will have no effect - the last functional value will be used.

Содержание Conan

Страница 1: ...CLF Conan V 2 11 JULY 2015 C o n a n ...

Страница 2: ...Dimensions All dimensions are in millimeters 2 ...

Страница 3: ...erfect condition and rated for the current requirements of all connected devices l Power input and throughput cables must be rated 20 A minimum have three conductors 1 5 mm 16 AWG minimum conductor size and an outer cable diameter of 5 15 mm Cables must be hard usage type SJT or equivalent and heat resistant to 90 C minimum l Use only PowerCon cable connectors to connect to power input sockets Use...

Страница 4: ...ure in any way not described in this manual l Do not look continuously at LEDs from a distance of less than 8 3 meters from the front surface of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irritation At distances of 8 3 meters and above light output is harmless to the naked eye provided that the eye s ...

Страница 5: ...necting the data link 9 Tips for reliable data transmission 9 Physical installation 10 Fastening the fixture to a flat surface 10 Setup 11 Control panel and menu navigation 11 DMX address setting 11 WDMX control 11 Control mode 12 Restoring factory default settings 12 Operation and effects 13 Effects 13 DMX protocol 14 Standard mode 14 Manual mode 16 Onboard control menus 17 18 Specifications 19 C...

Страница 6: ...achment point Display DMX input DMX output AC mains power throughput AC mains power input Note head fan grill in production models is rotated 90 compared to this illustration G Clamp with Quicklock 875760 Optional 6 Antenna wireless solutions optional ...

Страница 7: ...ters l DMX control Warning Read Safety Information on page 3 before installing powering operating or servicing the fixture Before applying power to the fixture l Carefully review Safety Information starting on page 3 l Check that the local AC mains power source is within the fixture s power voltage and frequency ranges l See Power cables and power plug on page 8 Install a PowerCon power input conn...

Страница 8: ... a building electrical installation if you want to install it permanently or a power plug that is suitable for the local power outlets can be installed on the power cable Warning Check that the voltage range specified on the fixtures serial number label matches the local AC mains power voltage before applying power to the fixture The fixtures accept AC mains power at 100 240 V nominal 50 60 Hz Do ...

Страница 9: ... connect more than ten fixture fixtures in total to AC mains power in one interconnected chain Relaying power to other devices Data link A DMX 512 data link is required in order to control a fixture via DMX The fixture has 3 pin XLR connectors for DMX data input and output The pin out on all connectors is pin 1 shield pin 2 cold and pin 3 hot Or the fixture has 5 pin XLR connectors for DMX data in...

Страница 10: ...he weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or air vents in the base may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment point see Fixture overview on page 6 ...

Страница 11: ...controller For independent control each fixture must be assigned its own control channels The DMX address is configured using the DMX ADDRESS menu in the control panel Press the button UP to switch off Wireless DMX or disconnect with all connected Transmitters Press the button DOWN to set the unit in the ready to connect with all not connected transmitters mode If you press the mode button on the ...

Страница 12: ...ing It gives a virtually instantaneous reaction when you dim from one intensity to another but dimming slowly from one intensity to another may appear slightly uneven l The SMOOTH setting gives smoother dimming during slow changes in intensity but it limits the speed of dimming changes slightly This makes it ideal for slow smooth dimming but a short time lag may be noticeable if you try to dim qui...

Страница 13: ...hanical color wheel and let you snap between 33 different full LEE referenced colors You can also scroll continuously forwards or backwards through the colors or display random colors at variable speed Color wheel priority The color wheel effect channels for the Beam have priority and override any color set on the Beam RGBW channels To use the RGBW and RGB channels you must set the color wheel eff...

Страница 14: ...low Shutter open Strobe 7 burst pulse fast slow Shutter open Strobe 8 random burst pulse fast slow Shutter open Strobe 9 sine wave fast slow Shutter open Strobe 10 burst fast slow Shutter open Beam Dimmer 0 100 intensity Zoom Wide narrow Fixture control settings No function 1 Reset entire fixture No function 2 Fan mode FULL No function 2 Fan mode REGULATED No function 3 Calibrated color output mod...

Страница 15: ...0 Beam Green Green 0 100 Beam Blue Blue 0 100 Beam white white 0 100 Beam CCT No Function CTC 10 000K 2 500K RGBW color mixing enabled Percent 0 1 2 67 68 69 70 78 79 80 81 89 90 91 92 93 94 95 96 97 98 100 0 100 0 100 0 100 0 100 0 07 8 100 DMX Value 0 9 10 174 175 179 180 201 202 207 208 229 230 234 235 239 240 244 245 249 250 255 0 255 0 255 0 255 0 100 0 19 20 255 Standard Note DMX values labe...

Страница 16: ...16 Manual mode Percent 0 100 0 100 0 100 0 100 0 100 DMX Value 0 255 0 255 0 255 0 255 0 255 Manual 1 1 2 3 4 Manual ZOOM Function RED 0 255 GREEN 0 255 BLUE 0 255 WHITE 0 255 Wide narrow ...

Страница 17: ... Factory calibration mode RGBW to white is Factory calibration 10 Auto programs available Select the step 0 20Hz Select strobe frequency transition time of last step to current step 0 step time DIMMER RED GREEN BLUE WHITE ZOOM STROBE FANS Cooling fan speed thermostatically regulated Max cooling fan speed DIMMER MODE Linear dimming curve Square law dimming curve Inverse square law dimming curve S c...

Страница 18: ...brate by DMX control to enter dmx controller calibration channel 4 is set to 245 249 Percent 0 100 0 100 0 100 0 100 0 89 90 95 96 97 98 10 0 99 100 0 100 0 100 0 100 0 100 DMX Value 0 255 0 255 0 255 0 229 230 234 240 244 245 249 250 255 0 254 255 0 255 0 255 0 255 0 255 channel 1 2 3 4 5 6 7 8 9 Function No function No function No function No function 5 come back to DMX mode No function 5 turn o...

Страница 19: ...ak angle Optics Light source Osram Ostar high power long life emitters Control and Programming Control DMX DMX channels 4 10 Setting and addressing Control panel with backlit graphic display Protocol USITT DMX512 A Construction Color Black Housing High strength die casting aluminum Protection rating IP 20 Installation Orientation Any Minimum distance to combustible materials 100 mm from fixture Mi...

Страница 20: ...uto ranging electronic switch mode Power consumption all effects static zero light output 15 W Thermal Cooling Forced air temperature regulated low noise user definable levels Maximum ambient temperature Ta max 40 C Minimum ambient temperature Ta min 5 C Total heat dissipation calculated 10 820 BTU hr 20 ...

Отзывы: