Steamer overfills
(Water sprays into the
cooking cabinet)
Does
the water level in the
sight glass stop at the
HI (short) probe on the
initial fill?
Start
Does
water spray in the
cabinet before the
water reaches the HI
(short) probe?
There is an obstruction in
the plumbing to and from
the sight glass. Remove
the debris (delime
thoroughly).
Is
there 120 VAC
across the coil of ;the
fill solenoid when the
HI (short) probe is
submerged?
Remove the
wire from the Fill
terminal on the water
board. Is there 120 VAC
across the coil of the
fill
solenoid?
No
Yes
No
Replace the three
minute timer.
Yes
With HI and C
terminals on the
water board jumped,
Is there 120 VAC
between terminals N
and Fill?
No
Replace the water
level board.
Yes
Is
there debris on
the HI (short)
probe?
No
Clean or replace
the probe
assembly.
Yes
Replace the wire
to the probe
assembly
No
Yes
Replace the fill
solenoid
No
Does
the water rise in the
sight glass when steam
is generated and 0 VAC
to the fill solenoid?
Yes
Replace the fill
solenoid
No
Does
the rise in the water
level in the sight glass
stop when the cooking
cabinet door is
opened?
Yes
There is an
obstruction in the
generator causing
it to pressurize.
Delime the steam
generator
thoroughly.
No
There is an
obstruction in the
drain. Remove the
obstruction.
Yes
PROBLEM:
21CET8
21CET16
24CEA10
Steamer overfills.
(Water sprays into cooking
cabinet)