Steamer wont fill.
Is there supply
voltage to the
steamer?
Yes
Supply power to
the steamer.
No
Is there water
to the
steamer?
Supply cold water
to the steamer.
No
Yes
Is there 120 VAC
between the H and N
on the water board?
Replace the on/off
rocker switch.
No
Yes
Is there
120 VAC
between Fill and
N on the water
board?
Yes
Remove
the wire from the HI
terminal on the water
board. Is there 120 VAC
between Fill
and N?
No
Replace the water
board
No
Is there
debris on the
HI probe in the
probe assy?
Yes
Replace the wire
to the Hi probe.
Clean the probes
or replace the
probe assy.
No
Yes
Is there
120 VAC across
the coil of the fill
solenoid?
Yes
Is
water leaving
the fill
solenoid?
Replace wiring to
the fill solenoid.
No
Yes
Replace the fill
solenoid
No
Is there
120 VAC across
the coil of the
drain valve?
Yes
Does
the steamer have
the optional
intermittent
blowdown timer?
No
Replace wiring to
drain valve.
No
Is
there 120 VAC
between terminals
2&3 on the timer?
Is water
draining from
the generator?
Replace the drain
valve.
Yes
Yes
Replace the
intermittent
blowdown timer.
Yes
Yes
Replace the wiring
to the intermittent
blowdown timer.
No
No
PROBLEM:
21CET8
21CET16
24CEA10
Steamer wont
fill
If water is leaving
the fill solenoid
and not draining
from the generator
where is it going?
check for leaks..