PROBLEM:
21CET8, 21CET16, 24CEA10
Electronic timer displays "PAUS" and won't count down
Timer displays "paus"
and won't count down
Is steam heating
the cooking
cabinet above 192
degrees (the set
temp of the
thermo-switch)?
Does the timer
count down when
the thermo-switch
is bypassed?
Yes
See
Steamer
won't steam
No
Replace the
electronic timer
No
Replace the
thermo-switch
Yes
PROBLEM:
21CET8, 21CET16, 24CEA10
Steam leaks around the door.
Steam leaks
around the
door
Is
COLD
water
supplied to both
water lines to the
steamer?
Supply cold
water(35-60 psi) to
the steamer.
No
Is the door gasket
physically
damaged?
Yes
Turn over the
gasket or
replace it.
Yes
Is the door out of
alignment?
No
Replace the
door bearings
and pins.
Yes
Is the drain
obstructed?
No
Remove the
obstruction
Yes
Is there 120 VAC
across the coil of
the condensate
solenoid?
No
Replace the
wiring to the
condensate
solenoid.
No
Is the solenoid
opening?
Yes
Replace the
condensate
solenoid.
No
Replace the
condensate spray
nozzle
Yes