background image

PARTS LIS

T

 - SKILLET BOTTOM 

 

Item No.

 

Part No.

 

Description

 

Qty.

 

1

 

SK50502

 

Burner

 

6,8

 

2

 

SK50520

 

Zip Tube (SGL, SGM-30-X)

 

1

 

 
 

SK50521

 

Zip Tube (SGL, SGM-40-X)

 

1

 

3

 

SK50553

 

Bracket, Pilot Mounting

 

1

 

4

 

FA10360

 

Screw. 10-32 x 1/4"

 

2

 

5

 

SK50363

 

Orifice, Zip Tube, Natural Gas

 

1

 

 
 

 
 

(0-2000 Ft Elev

.

 #61 Drill)

 

 
 

 
 

SK50669

 

Orifice, Zip Tube, Natural Gas

 

1

 

 
 

 
 

(2000-4000 Ft Elev

.

 #62 Drill)

 

 
 

 
 

SK50671

 

Orifice, Zip Tube, Natural Gas

 

1

 

 
 

 
 

(4000-6000 Ft Elev

.

 #63 Drill)

 

 
 

 
 

SK50364

 

Orifice, Zip Tube, L.P.

 

1

 

 
 

 
 

(0-2000 Ft Elev

.

 #72 Drill)

 

 
 

 
 

SK50670

 

Orifice, Zip Tube, L.P.

 

1

 

 
 

 
 

(2000-4000 Ft Elev

.

 #73 Drill)

 

 
 

 
 

SK50672

 

Orifice, Zip Tube, L.P.

 

1

 

 
 

 
 

(4000-6000 Ft Elev

.

 #74 Drill)

 

 
 

 

 

Содержание SGL-X

Страница 1: ...Repair Manual Free Standing Gas Skillets Models SGM X SGL X...

Страница 2: ...llet On Off Toggle Switch Electrical 7 Components Dwg Controls electrical power to the skillet Timer Control Knob This knob controls the bell timer and allows the Electrical operator to select a time...

Страница 3: ...Screw 10 32 x 1 4 2 5 SK50363 Orifice Zip Tube Natural Gas 1 0 2000 Ft Elev 61 Drill SK50669 Orifice Zip Tube Natural Gas 1 2000 4000 Ft Elev 62 Drill SK50671 Orifice Zip Tube Natural Gas 1 4000 6000...

Страница 4: ...Pilot L P 0145 1 13 KE51155 Combination Gas Control Valve Natural 1 Gas 24 VAC Spark Ignition KE51163 Combination Gas Control Valve L P 1 24 VAC Spark Ignition SK50608 Combination Gas Control Valve N...

Страница 5: ...ELECTRICAL COMPONENTS 4...

Страница 6: ...Fuse 1 1 2 Amp Spark Ignition 1 KE51140 Fuse 4 10 Amp Manual Ignition 1 15 SK50680 Switch Rocker Momentary 1 16 SK50728 Capacitor 20 MFD Silver Metal 1 16a Capacitor 30 MFD Silver Metal 1 Please orde...

Страница 7: ...lve 1 11 FA19060 Set Screw 8 32 x 1 8 1 12 SK00241 Push Button 1 13 14 KE00508 Hand Wheel 1 14 FA19501 Set Screw 3 8 16 x 3 8 1 15 SK50556 Bushing Hand Wheel 1 16 SK50602 Hydraulic Pump 1 17 FA31009 L...

Страница 8: ...8 Sleeve 1 10 SK50666 Roller 1 11 SK50604 Bracket Relief Valve 1 12 SK50628 On Tubing 77 SGL 30 X 1 SK50629 Oil Tubing 88 1 4 SGL 40 X 1 SK50630 On Tubing 86 1 2 SGM 30 X 1 SK50631 Oil Tubing 97 3 4 S...

Страница 9: ...HYDRAULIC JACK ASSEMBLY 8...

Страница 10: ...Mounting Bracket Hydraulic Jack 1 18 FA31009 Lockwasher 5 16 2 19 FA20010 Hex Nut 5 16 18 2 20 SK50552 Mounting Pin Bottom Jack 1 21 FA10032 Screw 4 40 x 5 8 2 22 FA32002 Tooth Lockwasher 4 2 23 FA32...

Страница 11: ...ELECTRIC JACK ASSEMBLY 10...

Страница 12: ...Bottom Jack 1 14 FA20010 Hex Nut 5 16 18 2 15 FA31009 Lockwasher 5 16 2 16 SK50542 Bracket Mounting Electric Jack 1 17 FA30078 Washer 2 18 FA10603 Bolt 5 16 18 x 3 4 2 19 SK50644 Spacer L H 3 16 Thick...

Страница 13: ...Piece 1 4 20 x 1 2 2 7 KE50122 Spring Hinge 30 Gal 1 KE50121 Spring Hinge 40 Gal 1 8 KE51217 Cylinder Hinge 1 9 KE50824 Bearing Hinge 1 10 SK50209 Washer 1 11 SK00101 Bolt 3 8 16 x 1 1 Use only replac...

Страница 14: ...ob 3 4 9 SK00175 Deflector Assy 30 Gal 1 SK00176 Deflector Assy 40 Gal 1 The first figure applies to 30 gal skillets the second figure applies to 40 gal skillets Use only replacement parts which are f...

Страница 15: ...3 SE50022 Yoke Connection Kit 1 4 FA00016 0 Ring 1 5 FA95022 Retaining Ring 1 6 KE51736 Spout Nut 1 7 KE50832 3 4 Spout 10 A x 9 B 1 8 KE51401 Single Pantry Control Valve c w Item No 2 1 9 KE51403 Do...

Страница 16: ...2 No Correct external power supply problem 2 Is the main power lower pilot light Yes Go to step 6 illuminated No Go to step 3 3 Is the 4 10 amp fuse manual ignition Replace blown fuse 1 1 2 amp fuse s...

Страница 17: ...ment Procedure and adjust flame if necessary If adjustment is not required or unsuccessful replace defective pilot flame sensor 17 Yes Go to step 19 Look through peep hole Is a spark being generated N...

Страница 18: ...ot Flame Adjustment and Gas Pressure Adjustment Procedure If this does not correct the problem check incoming operating gas supply It should be minimum 7 WC natural gas or 12 WC LP gas If gas pressure...

Страница 19: ...units go to step 4 On 208 240V units is either one of the 10 amp fuses blown No Go to step 3 3 Yes Go to step 4 Is there 120 VAC present at output of 208 240 120 VAC transformer No Replace defective...

Страница 20: ...W C natural gas and 11 W C LP gas 3 Turn gas pressure adjustment screw under cover screw clockwise to increase or counterclockwise to decrease gas pressure 4 Replace cover screw PILOT FLAME ADJUSTMEN...

Страница 21: ...Remove hose from tank and turn jack upside down Push in on the jack s piston rod Oil with air bubbles will seep out the end of the hydraulic hose Continue pushing down on the rod until all air bubbles...

Страница 22: ...nto new tank 7 Tilt oil tank up at back so that oil flows toward pump 8 Turn pump shaft counter clockwise until oil starts to seep out of elbow 9 Set pump and oil tank down so that oil tank is sitting...

Страница 23: ...n approximately 1 8 in the hole where the first slotted screw was removed from 5 Remove second slotted screw 6 While holding Allen wrench remove pin 7 Turn Allen wrench clockwise to tighten or counter...

Страница 24: ...WIRING DIAGRAM SPARK IGNITION 23 WIRING DIAGRAM MANUAL IGNITION...

Отзывы:

Похожие инструкции для SGL-X