GENERAL 

Installation of the kettle must be accomplished by
qualified electrical installation personnel working
to all applicable local and national codes.
Improper installation of product could cause injury
or damage.

This equipment is built to comply with applicable
standards for manufacturers. Included among
those approval agencies are: UL, NSF, ASME/Ntl.
Bd., CSA, CGA, ETL, and others. Many local
codes exist, and it is the responsibility of the
owner/installer to comply with these codes.

Note:

Maximum voltage for LVD (low volt

directive for Europe) to be 440 volts for CE
marked appliances.

INSPECTION

Before unpacking visually inspect the unit for
evidence of damage during shipping.

If damage is noticed, do not unpack the unit, follow
Shipping Damage Instructions shown below. 

SHIPPING DAMAGE 
INSTRUCTIONS

If shipping damage to the unit is discovered or
suspected, observe the following guidelines in
preparing a shipping damage claim. 

1.

Write down a description of the damage or the
reason for suspecting damage as soon as it is
discovered. This will help in filling out the claim
forms later. 

2.

As soon as damage is discovered or
suspected, notify the carrier that delivered the
shipment. 

3.

Arrange for the carrier's representative to
examine the damage.

4.

Fill out all carrier claims forms and have the
examining carrier sign and date each form. 

INSTALLATION

The first installation step is to refer to the
Specification Sheets or Specification Drawings for
detailed clearance requirements of the kettle.
Next, carefully cut open the shipping carton for
easy removal of the kettle.

ASSEMBLY

Table-top models (12 gallon) must be positioned on
a firm, level stand, or existing counter top, and
bolted in place. These models are supplied with four
threaded mounting bushings welded to the
underside of the base. An optional support stand
with level adjustable legs is available. Once the kettle
is secure, screw tilt handle into the threaded hole
provided at the right side of kettle.

Floor Type Leg Mount Models (20 gallon)

Position on a firm, level surface, and bolt flanged
feet in place. Once the kettle is secure, screw tilt
handle into the threaded hole provided at the right
of kettle.

ELECTRICAL

ENSURE THE ELECTRICAL SUPPLY MATCHES
THE KETTLE'S REQUIREMENTS AS STATED
ON THE RATING LABEL.

This kettle is built to comply with applicable
standards of manufacturers. Included among
these approval agencies are UL, NSF, ASME/Ntl.
Bd., CSA, ETL, and others. Many local codes
exist, and it is the responsibility of the owner and
installer to comply with these codes.

The electrical supply must match the power
requirements specified on the kettle’s rating plate.
The copper wiring must be adequate to carry the
required current at the rated voltage.

Note:

Maximum voltage for LVD (low volt

directive for Europe) to be 440 volts for CE
marked appliances.

INSTALLATION

Содержание MKET-12-T

Страница 1: ...n Operation Electric Table Top Mixers SE95015 Rev 4 1333 East 179th St Cleveland Ohio U S A 44110 Phone 216 481 4900 Fax 216 481 3782 Visit our web site at www clevelandrange com Cleveland Enodis For a complete Service Manual refer to www clevelandrange com ...

Страница 2: ...s may be extremely hot Use protective equipment Keep appliance and area free and clear of combustibles Stand clear of product discharge path when discharging hot product Wear protective equipment when discharging hot product Do not lean on or place objects on kettle lip Do not attempt to operate this appliance during a power failure Keep clear of pressure relief discharge Keep hands away from movi...

Страница 3: ... sign and date each form INSTALLATION The first installation step is to refer to the Specification Sheets or Specification Drawings for detailed clearance requirements of the kettle Next carefully cut open the shipping carton for easy removal of the kettle ASSEMBLY Table top models 12 gallon must be positioned on a firm level stand or existing counter top and bolted in place These models are suppl...

Страница 4: ... the kettle on read the vacuum pressure gauge The gauge s needle should be in the green zone 3 Place the kettle s power ON OFF switch to the ON position 4 Turn the temperature control knob to 1 Min The green LED light should remain lit indicating the burner is lit until the set temperature is reached 124 F 50 C Then the green light will cycle on and off indicating the element is cycling on and off...

Страница 5: ...nches of mercury 6 Pressure Relief Valve This valve is used to vent the kettle and in the unlikely event there is an excess steam build up in the jacket this valve opens automatically to relieve this pressure 7 Kettle Tilt Handle Used for tilting the kettle 8 Marine Lock Prevents unit from accidental tilting 9 Agitator Speed Control Knob This control allows the operator to select agitator speed in...

Страница 6: ...icator Light Red 4 should not be lit when kettle is in the upright position during kettle operation This light indicates that the elements have been automatically shut off by the kettle s safety circuit It is however normal for the red light to come on when the kettle is in a tilted position 6 When cooking is completed place On Off Toggle Switch 1 to the OFF position 7 Pour the contents of the ket...

Страница 7: ...ide to side play Lock should remain fully over stop pin when pushed to it s maximum side to side play Figure B 3 Check that the kettle when pushed fully upright moves the lock to a closed position To check this A Hold the latch firmly in the unlocked position while tilting the kettle back to an upright position B The kettle sidebox will force the lock into a new position C Hold the lock in this po...

Страница 8: ...ure setting 6 Drain unit 7 Rinse interior thoroughly 8 If the unit is equipped with a Tangent Draw Off Valve clean as follows a Disassemble the draw off valve first by turning the valve knob counter clockwise then turning the large hex nut counter clockwise until the valve stem is free of the valve body b In a sink wash and rinse the inside of the valve body using a nylon brush c Use a nylon brush...

Страница 9: ...ated Replace shoulder bolt and latch and tighten firmly 7 Replace lockwasher and locknut inside the console and tighten firmly 8 Test Marine Lock See Marine Lock Testing Procedure 9 Replace console cover Latch Shoulder Bolt Lockwasher Locknut Carefully apply locktight to the final two threads AGITATOR ASSEMBLY 1 Place the Kettle s On Off Toggle Switch 1 to the OFF position 2 Raise Mixer Bridge 11 ...

Страница 10: ...ot be seen play it safe and use a soft cloth or plastic scouring pad 3 Use alkaline alkaline chlorinated or non chloride containing cleaners While many traditional cleaners are loaded with chlorides the industry is providing an ever increasing choice of non chloride cleaners If you are not sure of chloride content in the cleaner used contact your cleaner supplier If your present cleaner contains c...

Страница 11: ...ghtness If loose apply lock tight and reinstall Check handle knob is on end of handle and firmly tightened If loose apply lock tight and reinstall PRESSURE GAUGE Check that the gauge does not have moisture on its inside face Replace if moisture is present Check that the gauge shows a vacuum needle is well into the Green zone when cold and shows between 25 40 psi when unit is hot If not follow Vacu...

Страница 12: ...ith or bypassing controls is a very dangerous practice and unfortunately we have seen several cases of this Fol lowing is a short list of the most common and the most dangerous alterations performed on kettles Plug Tube diameter reduced Frozen stuck or plugged Plumbed to drain or water line 1 2 3 4 Incorrect Installations 1 Safety valve has plug threaded into the discharge opening prevent ing any ...

Страница 13: ...afety thermostat probe is removed from tubing 3 Safety thermostat electrical connec tion is bypassed Low Water Level Probe Probe bypassed by running A an addi tional wire Probe properly attached 260º 270º MAXIMUM KETTLE TEMPERATURE 265º If maximum temperature is not in this range on empty kettle refer to the Calibrat ing Procedure in the unit s Installation Operation Service Manual Operating Therm...

Отзывы: