the amber light will go out The energy source cannot be activated until the boiler contains sufficient water indicated
by the amber light. The "steam" switch must be pushed to re-start the steamer after it is shut off for any reason
(including a momentary power interruption). Do not attempt to start or operate this appliance during a power failure.
Whenever the amber light is illuminated, the heater, steam supply, or burners are off, and no steam is being
generated.
NOTE FOR UNITS CONTAINING GAS-FIRED BOILERS ONLY:
If the burners fail to ignite in four seconds,. a
safety circuit will de-energize the system. In this event, momentarily press the power switch to the "off"
position, then back to the
"on"
position. (The "steam" switch amber light should be on. Wait 5 minutes, then
press the "steam" switch to start the burner ignition cycle once again.)
10. Check to ensure that the
water in the boiler's sight gauge glass stays at about 2/3 full when the boiler is started up
and operated.
11. Check to ensure that the steam pressure gauge registers 10 psi. The steam pressure is factory adjusted to provide
the proper pressure in
some cases, however the factory setting may shift due to shaking in transit, and resetting
will be required after installation. Proper adjus tments and maintenance procedures should be made only by
qualified service personnel. The factory pressure settings shown in the accompanying chart should never be
exceeded.
12. When the installation is complete and free of leaks, refer to the OPERATIONAL FUNCTIONS section, in order to
understand proper operation of the unit.
GUAGE PRESSURE READING WITH NO STEAM FLOW (STATIC PRESSURE)
Self-Contained Steam Generator Gas or Electric
Self-Contained Steam Coil Generator
Direct-Connect (To “House
Steam Supply)
Equipment
Steamer’s
Pressure
Reducing
Valve
Operating
Pressure
Switch
High Limit
Safety
Pressure
Switch
Operating
Pressure
Switch
High Limit
Safety
Pressure
Switch
Steam
Supply
Pressure
Range
Steamer’s
Pressure
Reducing
Valve
Steam Supply
Pressure
Range
Steam Generator Only 5 psi
N/A
5 psi
10 psi
5 psi
10 psi
30-45 psi
N/A
N/A
Pressure Steamer
N/A
5 psi
10 psi
5 psi
10 psi
30-45 psi
5 psi
12-45 psi
Pressure Steamer
With Any Kettle
5 psi
10 psi
15 psi
5 psi
10 psi
30-45 psi
5 psi
12-45 psi
Steam Generator Only
10 psi
N/A
10 psi
15 psi
10 psi
15 psi
30-45 psi
N/A
N/A
Kettle Only
N/A
10 psi
15
psi
N/A
N/A
N/A
N/A
5-45 psi
Convection Steamer
With or Without Kettles
N/A
10 psi
15 psi
10 psi
15 psi
35-45 psi
10 psi
15-45 psi
Kettles are to be connected to the “house” steam supply.
INSTALLATION CHECK
Proper operation
of
the Cleveland SteamPTO XVl Steamer is dependant upon proper installation. After the steamer has
been installed,
a few quick checks could save unnecessary service calls.
1. The SteamPro'" XVI Steamer requires a cold water connection for proper, efficient operation. DO NOT USE HOT
WATER. The cold water must be connected to the line strainer located at the front lower-right of the steamer base.
Ensure that the manual water supply valve is open.
The cold water feed One must maintain 40 to 60 psi constant flow pressure, and not experience a pressure drop
when other appliances
are used. Both the hot and cold water lines should maintain 35 to 60 psi flow pressure.
2. The unit must be level.
3. On electric units, the supply voltage must agree with the voltage Indicated on the rating plate inside the base cabinet,
and with the voltage
shown on the packing slip. The unit must be protected with a separate fused disconnect and be
properly grounded, in accordance with the National Electric Code.
Содержание 9-PCDM-L
Страница 26: ...25 Power Supply 100766 Power Supply Board ...
Страница 30: ...1 20005 Switch Rocker Red 29 ...
Страница 31: ...1 19972 Switch Thermal Close 193 5 Deg F Open 173 5 Deg F PCI 30 ...
Страница 32: ...1 101233 Water Regulator Assembly Wilkins 2 100218 Regulator Water Pressure 3 4 x 3 4 PCL 31 ...
Страница 39: ...Drain Manifold Assembly 1 1008983 Drain Manifold Assembly 2 13252 Manifold 1 500 Dia 8 1 2 Length Black ...
Страница 40: ...39 ...
Страница 41: ...40 ...