WATER QUALITY REQUIREMENT
The recommended minimum water quality standards whether
untreated or pre-treated, based upon 10 hours of use per day,
and a Daily Slowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR greater than 7.5
Consult a local water treatment specialist for an onsite
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The use
of highly mineralized water will mean that more
frequent servicing of the steam generator will be necessary.
the fact that a water supply is potable is not proof that it will be
suitable for the generator.
STEAM COIL
WATER
DRAINAGE
ELECTRIC
CLEARANCE
1 ½”
IPS common
drain.
Do not connect any
other units to this drain.
Steam Supply
Piping: • ¾” IPS
min. for 35 to 50 psi.
• For pressure
above 50 psi, a
pressure reduc ing
valve must be
specified.
35 psi. min. 60 psi ©
max. 3/8" IPS cold
water.
Steam Cold Drain
•3/4” IPS.
Do not
connect to common
drain.
115V-1 PH
25 watts per
compartment.
RIGHT - 12.00"
If adjoining wall or
equipment is over
30.00" high.
LEFT = 0”
REAR =0”
Cleveland/ALCO reserves right of design improvement or modification, as warranted.
10.
SHORT FORM SPECIFICATION
Shall be Two Compartments, CLEVELAND Pressure/
Convection Steamer, steam coil generator, Model 9-
PCSM-L, 115 volts, 60 Hz, 1 phase. Pressure/Convection
modes to be selectable at user's option with no restrictions
as to any combination of modes. Type 304 Stainless Steel
exterior paneling and cooking compartments. Insulated
compartments. One solid state, 99 minute digital timer with
touch control per compartment. Audible and visual signals
for cycle completion and steam shut-off. Separate visual
indication for each operational mode.
•
Each compartment has capacity for:
Eight, 12” x 20” x 2 ½” pans.
•
Many local codes exist and it is the responsibility of
the owner and installer to comply with those codes.
•
Cleveland/ALCO equipment is built to comply with
applicable standards for manufactures. Included
among those approval agencies are: UL, A.G.A.,
NSF, ASME/N.Bd., CSA, ETL, and others.
Scale .50 "=1’
Содержание 9-PCDM-L
Страница 26: ...25 Power Supply 100766 Power Supply Board ...
Страница 30: ...1 20005 Switch Rocker Red 29 ...
Страница 31: ...1 19972 Switch Thermal Close 193 5 Deg F Open 173 5 Deg F PCI 30 ...
Страница 32: ...1 101233 Water Regulator Assembly Wilkins 2 100218 Regulator Water Pressure 3 4 x 3 4 PCL 31 ...
Страница 39: ...Drain Manifold Assembly 1 1008983 Drain Manifold Assembly 2 13252 Manifold 1 500 Dia 8 1 2 Length Black ...
Страница 40: ...39 ...
Страница 41: ...40 ...