Boiler won't fill.
Yes
No
No
Yes
No
Yes
Yes
No
No
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
Yes
Yes
No
PROBLEM:
Gas boiler
won't fill
Yes
Is there power to
the steamer?
Is there water to
the steamer?
Supply power
to the steamer.
Supply cold
water to the
steamer.
Replace the
on/off rocker
switch .
Is there 120 VAC
between the L1
and L2 on the
water board?
Is there
120 VAC between
L2 and W F on the
water board?
Replace the
wiring to the fill
solenoid.
Is there
120 VAC across
the coil of the fill
solenoid?
Replace the fill
solenoid
Yes
Is
water leaving the
fill solenoid?
Replace wiring
to drain
solenoid.
Does
the steamer have
the optional
intermittent
blowdown timer?
Replace the
wiring to the
intermittent
blowdown
timer .
Is
there 120 VAC
between terminals
2&3 on the timer?
Replace the
intermittent
blowdown
timer.
Is there
120 VAC across
the coil of the
drain valve?
Is water draining
from the
generator?
If water
is leaving the fill
solenoid and not
draining from the
generator where is it
going? check for
leaks..
Remove
the wire from the HI
terminal on the water
board. Is there 120
VAC between L2 and
WF?
Replace the
water board
Is there
debris on the HI
probe extension?
Replace the
wire to the Hi
probe.
Clean or
replace the
probes
extension.
Replace the
drain valve.
No
Содержание 24-CGM-200
Страница 3: ......
Страница 5: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 21: ...1333 East 179th Street Cleveland Ohio 44110 Phone 216 481 4900 Fax 216 481 3782 ...
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......