![Cleode ZigBee ZMOVE Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/cleode/zigbee-zmove/zigbee-zmove_user-manual_2622566010.webp)
ZMOVE – User Manual
UM_ZMOVE_20090731_001_04_00
CLEODE Page 10 sur 18
Alarms cluster:
This cluster is used to signal an alarm. In the case of ZMOVE, only the low battery power
level is processed. If the battery power level is too low (under 2,4V) the
AlarmCount
value changes to 1 and a command message is send to coordinator.
Attribute
Attribute ID
AlarmCount
0x0000
Occupancy sensing:
This cluster is used to signal a motion or not by
Occupancy
attribute. On motion detection
and at the end of detection on report of
Occupancy
attribute value is transmitted on the
network.
Attribute
Attribute ID
Occupancy
0x0000
OccupancySensorType
0x0001
PIROccupiedToUnoccupiedDelay
0x0010