III.5 Restart manually the pairing 

To pair the ZGas again in a ZigBee® network, proceed as follows: 

 

1)

 

Allow  the  addition  of  ZigBee® object in your 

network  (see  the  manual  of  your  ZigBee® 
coordinator) 

 

 

 

2)

 

Hold 3 seconds the pairing button. 

 

 

3)

 

If  the  ZGAS  was  not  associated  it  will  flash 

rapidly during 20 seconds. The ZGAS is looking 
for a coordinator during this flashing. 

 

 

 

4)

 

If  the  association  is  successful,  the  red  light 

turns on for 2 seconds and then turns off. 

 

 

 

The ZGas saves network parameters automatically on which it is already connected.  

It is therefore possible in a network change (or when the network coordinator has been 
changed) that the product can’t fit on the new network. 

In this case, it is necessary to clear the existing network settings by performing a reset 
procedure (see paragraph below). 

 

 

 

If the light is not flashing after performing a long press of 3 seconds, the ZGas is already 
associated in a network. 

   

Appui long 3s 

(Push during 3s) 

Содержание ZGAS

Страница 1: ...ANNION France T 33 0 2 96 48 68 18 F 33 0 2 96 48 19 11 SA with capital of 167 200 450 570 767 RCS Saint Brieuc User Manual ZGAS Smoke detector and CO detector ZigBee Revision 6 date 10 22 2014 Status...

Страница 2: ...ces in order to comply with the warranty The warranty does not apply to replacement or repairs that may result from normal wear and tear of devices systems or products damage or accidents resulting fr...

Страница 3: ...04 2009 2 0 Cleode Validated document 09 04 2009 2 1 Cleode Add Technical features chapter 09 25 2009 3 0 Cleode Validated document 09 25 2009 3 1 Cleode Modification of autonomy period 01 05 2010 4 0...

Страница 4: ...4 sur 21 Reference documents N Document Description 1 ZigBee_Cluster_Library_Public ZigBee Cluster Library specification 2 ZigBee_Specification ZigBee specification 3 ZigBee_Home_Automation Home Auto...

Страница 5: ...I 3 MAINTENANCE 14 III 3 1 CHECK FUNCTIONALITY 14 III 3 2 MAINTENANCE 14 III 4 PAIRING THE PRODUCT FOR THE FIRST TIME 14 III 5 RESTART MANUALLY THE PAIRING 15 III 6 RESET OF NETWORK PARAMETERS OF ZGAS...

Страница 6: ...ZGAS CLEODE page 6 sur 21 List of figures FIGURE 1 EXPLODED VIEW PRODUCT 7 FIGURE 2 POSITIONING ON A LEVEL 10 FIGURE 3 CLEARANCES WHEN POSITIONING 11 FIGURE 4 MOUNTING OF ZGAS 12 FIGURE 5 CHANGING THE...

Страница 7: ...make a sound if an alarm is detected or on request from the ZigBee network For that it will make a sound symbolizing the type of abnormality detected 1 short beep means the battery is low 4 short bee...

Страница 8: ...fication time isn t exceeded Manual start of the associationphase Up to 20 seconds The device blinks slowly when he researches a coordinator Pairing OK 2 seconds Once associated the sensor turns on2 s...

Страница 9: ...rocedure of quick start 1 Install the product for details see section III 1 2 Pairing the product ZGAS in the ZigBee network for details see section III 4 3 The product is operational in your ZigBee n...

Страница 10: ...f housing The riskisgreateratnight it isrecommendedto place the sensors near bedrooms see in the bedroom The ZGas can cover an area of about 50 m of space without partitioning For optimum functionalit...

Страница 11: ...be heard from every bedroom with the door closed Where not to install Do not install outdoors Do not install in a garage Do not install near a heat source oven grill hob Do not install within 1 m arou...

Страница 12: ...wo holes 5 0mm in the ceiling use the wall mounting as a template and insert two plastic dowels in the holes 4 Fix the socket to the ceiling using the screws supplied 5 Insertand connecta newbatteryin...

Страница 13: ...ZGas proceed as follows 1 Unlock ZGas of its socket by turning it clockwise 2 Remove ZGas from its socket 3 Return the ZGas 4 Remove the old battery 5 Put a new battery 6 Fix the product to the mounti...

Страница 14: ...at mayaccumulate at the openings of the case III 4 Pairing the product for the first time To pair the ZGas in a ZigBee network proceed as follows 1 Allow the addition of ZigBee object in your network...

Страница 15: ...this flashing 4 If the association is successful the red light turns on for 2 seconds and then turns off The ZGas saves network parameters automatically on which it is already connected It istherefore...

Страница 16: ...I 6 Reset of network parameters of ZGas To clear the network parameters of ZGas proceed as follows 1 Press the pairing button during 5 seconds 2 If the product ZGas reset the red led blinks 2 times an...

Страница 17: ...n Device ID IAS Zone Endpoint 1 Clusters Server Client Basic 0x00 Power Configuration 0x01 Identify 0x03 Alarms 0x09 IAS Zone 0x0500 IAS Warning Device 0x502 IV 2 2Description of clusters Here is a br...

Страница 18: ...report of the battery voltage is available to monitor the battery IV 2 2 3 Cluster Identify Thiscluster is used to identify the device in the network By writing the value of the attribute IdentifyTim...

Страница 19: ...attribute is a bitmap The description of each bit is shown in the following table Bit Description Values 0 Monoxide Alarm 1 Alarmed 0 Not Alarmed 1 Smoke Alarm 1 Alarmed 0 Not Alarmed 2 Tamper 1 Tamp...

Страница 20: ...ur name companyandthe serial numberof the defective item to the support personnel The item shall then be returned to CLEODE with the following documents The RMA number A copy of the delivery slip A de...

Страница 21: ...ts should be sent to the following address or by email to CLEODE S A Technical and Maintenance Service 3 rue Thomas Edison 22300 Lannion FRANCE Phone 33 0 2 96 48 68 18 Fax 33 0 2 96 48 19 11 Email su...

Отзывы: