7.8
Replacing Filter Cartridges –Figures 32 and 33
WARNING
NO DUST IS SAFE TO BREATHE.
The inhalation of airborne dust can lead to
serious respiratory illness and death, serious
skin or eye irritation, or other health issues.
Always wear approved respiratory protection
when servicing the dust collector, while
handling filter bags and cartridges, and when
emptying the dust container. Toxicity and
health risk vary with type of media and dust
generated by blasting. The respirator must be
approved for the type of dust generated.
Identify all material being removed by blasting
and obtain a safety data sheet (SDS) for the
blast media
.
7.8.1
Shut the sequence switch, located on the
sequence-panel cover, OFF.
7.8.2
Close the air-supply valve and bleed all air from
the pulse reservoirs.
7.8.3
Refer to Figure 32 and unlatch the dust
container lid, pry off the lid from the container (the lid's
flexible inlet hose allows easy removal), and remove the
container.
7.8.4
Tie off or otherwise seal the top of the liner and
remove it from the container. Dispose of the sealed liner
into a suitable disposal receptacle.
Figure 32
7.8.5
Place a new liner inside the container and drape
it over the top edge. Reattach the container to the lid
and latch the lock ring, making sure the lid and clamp
are secure. Replacement liners are shown in Section
9.10.
7.8.6
Remove the dust-collector access door.
7.8.7
Loosen the cartridge retaining-nut at the bottom
of the hanger rod, as shown in Figure 33, and rock the
cartridge to loosen it from the cartridge plate.
7.8.8
Swing the bottom of the cartridge out through
the access door, and remove the retaining nut, lock
washer, and flat washer.
7.8.9
Slide the cartridge off the hanger rod.
7.8.10
Clean all parts that will be reused, especially on
the bottom side of the cartridge plate around the
cartridge sealing area. Scrape off any residual gasket
material from the sealing surface.
7.8.11
Slide new cartridge onto the hanger rod and
install the washers and retaining nut.
7.8.12
Swing each cartridge into the collector and
tighten the retaining nuts until the cartridges cannot be
moved by hand. Tighten each nut one additional full
turn.
7.8.13
Check the access door gasket for any condition
that will prevent the gasket from sealing. Replace the
gasket if necessary.
7.8.14
Attach the access door and tighten the nuts to
secure.
7.8.15
Reset pulse pressure to 60 psi, per Section 5.7
and reset the timer OFF time to 40 seconds, per Section
5.8.
Figure 33
7.8.16
Season cartridges per Section 7.9.
Cartridge Sealing Gasket
Hanger Rod
Filter Cartridge
Flat Washer
Lock Washer
Retaining Nut
Drum Liner
Latch Catch
Swing the catch
up to unlock the
lock-ring latch.
Latch
Pull the latch away
from the ring and
remove the ring.