![Clemco PULSAR IX Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/clemco/pulsar-ix/pulsar-ix_manual_2622429021.webp)
PULSAR
®
IX SUCTION BLAST CABINET
Page 20
© 2019 CLEMCO INDUSTRIES CORP.
www.clemcoindustries.com
Manual No. 23425, Rev. C, 07/19
all material removed by the blast process. Check with
proper authorities for disposal restrictions.
Figure 26
6.1.4.5
Place a new liner inside the container and drape
it over the top edge. Reattach the container to the lid
and latch the lock ring, making sure the lid and clamp
are secure.
6.2
Daily Inspection During Blasting – Have
Someone Do the Following:
6.2.1 Inspect cabinet for dust leaks:
During
operation, inspect cabinet door seals for media leaks.
Dust leaking from the inlet damper or other places on
the cabinet indicates saturated filter cartridge. Refer to
troubleshooting Section 8.15.
6.2.2 Check exhaust air for dust:
Dust discharge at
the dust-collector outlet indicates a leaking or damaged
filter cartridge. Immediately shut off the dust collector and
inspect the cartridges. Note that a small amount of dust
egress is normal for a short time before new cartridges
are seasoned.
6.2.3 Drain pulse reservoirs
: Open the petcock to
drain both pulse reservoirs at the end of each shift. Refer
to Figure 27.
Figure 27
6.3
Weekly Inspection and Maintenance Before
Blasting with Air OFF
6.3.1 Inspect view-window cover lens:
Inspect the
window cover lens. Replace as needed, per Section 7.3.
6.3.2 Inspect gloves:
Inspect gloves for wear. The
first sign of deterioration may be excessive static
shocks. Replace as needed, per Section 7.1.
6.3.3 Inspect BNP
®
gun assembly:
Inspect internal
parts of the BNP Gun for wear. Inspection and
replacement of the air jet cover before it wears through
will prolong the life of the jet. Replace parts as needed,
per Section 7.2.
6.3.4 Inspect media hose:
Inspect media hose for
thin spots by pinching it every 6 to 12 inches. Replace
the hose when it becomes soft.
6.3.5 Optional differential-pressure-gauge inline-
filter:
With the exhauster turned OFF, check the inline
dust filer for dust accumulation.
6.4
Weekly Inspection During Blasting – Have
Someone Do the Following:
6.4.1 Inspect flex hoses for leaks:
Inspect flex
hoses for wear and negative pressure leaks.
6.5
Monthly Inspection and Maintenance Before
Blasting with Air and Exhauster OFF
6.5.1 Reclaimer wear plate and liners:
Remove the
flex hose from the reclaimer inlet and use a light to
inspect the reclaimer wear plate or optional rubber
reclaimer liners for wear. If the rubber is worn through to
the backing metal, replace the wear plate, per Section
7.10 or rubber liners, per Section 7.11, as necessary.
Drain
Pulse Reservoir
Drum Liner
Latch Catch
Swing the catch
up to unlock the
lock ring latch.
Latch
Pull the latch away
from the ring and
remove the ring.
Lid Lock Ring