9
On the back-side of the cabinet is an earth screw. The connections have to be done
depending on the local conditions.
Ground wire, possible ground plates etc, are not part of the delivery.
(4) Test without blast media
(for transport damages).
−
Close the doors.
−
Press the green switch on the black box. The light must switch on and the
motor start.
−
Check if motor rotates in direction of the arrow. If not, reverse polarity of
the electrical connection by a qualified electrician.
−
When the light and the motor are switched on (green button), the cleaning
pulse for the dust collector cartridge can be heard in regular intervals (of
40s).
−
Pick up nozzle (gloves) and depress the foot pedal. The blast process
must start (air comes out the nozzle).
−
While the foot pedal is depressed, a second person opens first the right
and then the left door. At the same time the blast process should automat-
ically be interrupted (see door interlock adjustment in figure 3).
−
The blast process has to be interrupted by pushing the emergency stop
button.
−
If no troubles occur, the cabinet can be tested with blast media. Otherwise
go to section 6 for trouble-shooting.
(5) Fill in blast media.
−
When using clean blast media fill through cyclone access door.
−
If it is not sure that blast media is really clean, turn on motor (green
switch) and slowly fill blast media into the cabinet hopper.
−
Blast media will be cleaned during suction process.
−
To ensure a continuous operation and to prevent agglomeration of usable
blast media in dust collector during suction, the following minimum quanti-
ties are required:
⇒
Pulsar II 5 litre
(6) Test with blast media
−
Close the doors.
−
Adjust desired blast pressure.
−
Pick up gun (gloves) and start blasting by depressing the foot pedal. Di-
rect nozzle to grating.
−
During the blast process a second person checks for leaks (dust).
⇒
Doors.