![Clemco BNP 220 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/clemco/bnp-220/bnp-220_owners-manual_2622422019.webp)
19
5.4
After max. 50 h of blasting
Check and if necessary. replace /cleanse
(1) Blast gun and nozzle
Nozzle gasket.
(2) Moisture separator.
Clean filter and sight glass with soap and warm water
(3) Air hoses and blast hoses.
- gaskets of couplings for wear
-blast hose by hand for soft spots
(4) Blast pot
- pop up valve for wear by hand
-Verschleiß Verschlußkegel durch Abtasten mit Fingern überprüfen
5.5
After max. 150 h of blasting
(1) Gasket on cabinet doors.
(2) Filter cartridge.
- see 4.4.5
5.6
After other periodes of time
replace (even without wear) after maximal
Blsat hoses
6 years
Remote control hoses
6 years
Air hoses – external air supply
6 years
O-rings
5 years
Pop up valve (blast pot)
5 years
Gaskets
5 years
6
Troubleshooting
Problem
Probable cause
Remedy
(1) Poor visibility.
Exhaust motor does not rotate.
Slide damper in false position
See 4.4.3
Dirty filter cartridge.
Blow off filter cartridge.
replace (see 4.4.5).
Exhaust motor rotates in the wrong
direction.
Reverse polarity (only through licensed electrician).
Blast media breaks down rapidly
and creates dust
- lower blast pressure
- other media.
Blocked hose between blast
cabinet and reclaimer / cyclone
Check and if necessary disassemble hose and remove
dust and media.
Blockage is not the real cause.
Negative pressure.
Check the following components:
- Reclaimer door open or leaky.
- Test the connections of hose for leaks
- Suction hoses for wear.
- Dust leaking from dust conatiner