![Clemco BNP 220 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/clemco/bnp-220/bnp-220_owners-manual_2622422017.webp)
17
4.4.5
Pulsing (cleaning) dust collector cartridge / replace cartridge / disposal of residues
Replace cartridge
- pulse filter cartridge two times
-start again cabinet and turn off after more than 2min
+ ca. 5 minutes dedusting pulse
- push emergency stop
- close air supply
- depressurize installation (see 4.4.1)
- unscrew filter cover
- pull a
( ≥ 120 l)
plastic bag over the filter cartridge
- unscrew the nuts on the flange and pull out the filtercartridge with the
plastic bag.
- screw the new filter cartridge and take care of the position of the seal kit.
- Close dust collector cover
Empty dust container
-release the dust container from the cover
WARNING!
If
toxical residues, dispose dust as hazardous waste!
4.4.6
Window replacement
No.: Description
1
Filler strip
2
molding
3
Place for filler strip
4
Cabinet wall (fits into narrow slot)
5
Window tool
6
Filler strip
7
window (fits into expanded slot)
Pull filler strip from the window molding
Remove window
Push the window from the cabinet inside
Install a new window molding
Strip channel facing the front of the cabinetg
Install window
Push into the slot
Thread filler strip
With installation tool