18
4.4.7
Adjust door safety interlook
Nr:
Description
1
Door safety interlock
2
Nut for screw adjusting
3
Actuating screw for safety interlock
4
Cabinet door
5
Maintenance and cleanse
5.1
Preface
During operation the cabinets are exposed to wear. In order to ensure safe operation and high efficiency the blast machines
must be maintained regulary.
Warning! Risk of injuri!
Dicharge completely pressure during maintenance
jobs. (see 4.4.1)
5.2
If required
Check and if necessary. replace /cleanse
View window
-cover lenses
-if necessary window glass – see 4.4.6
gloves
5.3
After max. 8 h of blasting
Check and if necessary. replace /cleanse
Door interlock
-Open doors
- press pin (1). It has to return from alone.
Empty dust container.
- could be necessary already after one hour
Media recovery system (Reclaimer).
-empty screen
Turn off exhauster. This may be necessary more often - screen
magnet .
Nozzle and nozzle holder
Check gasket for wear and replace if it’s necessary