![Clemas & Co CS70 90B Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/clemas-and-co/cs70-90b/cs70-90b_operators-manual_2622305029.webp)
MAINTENANCE
UBF 28 NEW
Rev. 00
27/04/09
Pag. 32/36
5.3 PETROL ENGINE MAINTENANCE (MACHINE WITH ENDOTHERMIC MOTOR)
The motor is supplied with its own user manual which must used every time that maintenance is needed.
It is recommended to respect the following periods from one operation and the other:
Check the motor oil level
every 50 hours working and replace every 150 hours
Replace the air filter
every 100 hours working
Replace the motor oil filter
every 300 hours working
Check the tension of alternator belt
every 250 hours working
Settino and cleaning of injectors
every 1000 hours working
Register the cocker lever slack
every 1000 hours working
5.3.1
ELECTRIC EQUIPMENT CONTROL
It is very important to check the electric system up every two years. Disconnected cables or burnt cables must
be immediately replaced.
Interventions on the electric system must be carried out by a trained technician.
Every kind of intervention not explained in the operator manual must be carried out by
FIORENTINIs technicians.
5.4 TESTS TO BE CARRIED OUT
FREQUENCY
TECHNICIAN
CONTROLS
Safety device
2 years
Professional technician
Electric system
2 years
FIORENTINI technician
Brake system
3 years
Professional technician
Complete revision
5 years
FIORENTINI technician
MAINTENANCE
Clean dust tank
Daily
Operator
Vacuum filter
Daily
Operator
Cleaning of vacuum hoses
Weekely
Operator
Check the water level on
batterys
Weekely
Operator
Check if the battery cables
are well fixed
6 months
Professional technician
Check the motors carbon
brushes
Every year
Professional technician
Check the motor oil level
Weekely
Operator
Replace the motor oil filter
3 months
Operator
Replace the motor oil
Every month
Operator