Industrial Ethernet Unmanaged

7

Rear Panel View with DIN rail and Wall Mounting Brackets

(common rear view, may vary with model)

Models
SSF-1x2-RUGGED
SSF-1x4-RUGGED
SSF-1x4POE-RUGGED

DIN Rail Mounting Procedure

All Industrial switches from the SSF-RUGGED series have DIN rail bracket mounted 

from factory to the rear panel of the unit. If wall mounting is needed, first remove 

the DIN rail bracket. If DIN rail bracket needs to be reattached, make sure the 

spring is located on top position when unit is vertical.

Step 1

Step 2

Hold unit as in below image, making 

sure top of bracket with spring falls 

onto the top edge of TS-35 DIN rail.

Rotate and snap the unit onto the DIN 

rail by pushing the bottom unto the TS-

35 DIN rail. Unit will be secured to rail.

To remove unit from rail, repeat procedure in reverse. Start by pulling out the 

bottom of unit from the DIN rail.

Содержание SSF-1x4POE-RUGGED

Страница 1: ...SSF 1x2 RUGGED SSF 1x4 RUGGED SSF 1x4POE RUGGED Industrial Ethernet Switch Manual www cleerlinefiber com...

Страница 2: ...each UTP port supporting 802 3at PoE standard Reliability is highly ranked with an MTBF exceeding 120 000 hours All Industrial Ethernet models listed in this manual have passed IEC standards as descri...

Страница 3: ...950 CE LVD EN60950 CE LVD EN60950 Power input DC 48 52V DC 9 56V DC5V DC 48 52V Reverse Polarity Protection Yes Yes Yes PoE budget 60W None 120W Max PoE power per port 30W n a 30W Mounting DIN rail br...

Страница 4: ...ESD Level 3 Criteria B EN 61000 4 3 RS Level 3 Criteria A EN 61000 4 4 EFT Level 3 Criteria A EN 61000 4 5 Surge Level 3 Criteria B EN 61000 4 6 CS Level 3 Criteria A EN 61000 4 8 PFMF Magnetic Field...

Страница 5: ...king data traffic present UTP GREEN Off 10M 100M On 1000M on RJ45 port UTP YELLOW Off No link On UTP link OK Blinking data traffic present SYS Off Switch failed On Switch operating normally Note Gigab...

Страница 6: ...d PWR2 Observe voltage polarity when wiring power to the screw block connector Complete wiring without hot wires and with screw block connector disconnected from switch Installation Warning Ensure pro...

Страница 7: ...nit If wall mounting is needed first remove the DIN rail bracket If DIN rail bracket needs to be reattached make sure the spring is located on top position when unit is vertical Step 1 Step 2 Hold uni...

Страница 8: ...1 Use only indoors in climate controlled environments 2 Avoid looking directly into fibers or lasers while unit is powered 3 9 52V DC wide power input 48 52V DC for PoE PSE models not included FCC and...

Отзывы: