Industrial Ethernet Unmanaged

6

Top Panel View

(Common top view, may vary with model)

Models
SSF-1x2-RUGGED
SSF-1x4-RUGGED
SSF-1x4POE-RUGGED

Top panel has terminal screw block for PWR1 and PWR2 input as well as Alarm 

Relay output, alternate DC5V power jack and M3 grounding screw.

Alarm Relay Wiring

The alarm relay is closed during normal operation. If a fault is 

encountered (like power supply input lost) then relay contacts 

open until fault is remedied

Power input wiring

There are two independent and redundant power inputs, 

marked PWR1 and PWR2. Observe voltage polarity when 

wiring power to the screw block connector. Complete 

wiring without hot wires and with screw block connector 

disconnected from switch.

Installation Warning

Ensure proper electrical grounding availability before powering up device. The 

unit should be grounded using either the M3 grounding screw or with the DIN rail 

installation or wall mount brackets correctly grounded. Make sure power wires 

have adequate gauge for the power required by the unit to avoid risk of wires 

overheating and/or fire. This is especially important for the PoE PSE equipment. 

As general rule, keep power wiring on a different path from data cables and avoid 

crossing wires. This will reduce the risk of power surges on data ports.

Содержание SSF-1x4POE-RUGGED

Страница 1: ...SSF 1x2 RUGGED SSF 1x4 RUGGED SSF 1x4POE RUGGED Industrial Ethernet Switch Manual www cleerlinefiber com...

Страница 2: ...each UTP port supporting 802 3at PoE standard Reliability is highly ranked with an MTBF exceeding 120 000 hours All Industrial Ethernet models listed in this manual have passed IEC standards as descri...

Страница 3: ...950 CE LVD EN60950 CE LVD EN60950 Power input DC 48 52V DC 9 56V DC5V DC 48 52V Reverse Polarity Protection Yes Yes Yes PoE budget 60W None 120W Max PoE power per port 30W n a 30W Mounting DIN rail br...

Страница 4: ...ESD Level 3 Criteria B EN 61000 4 3 RS Level 3 Criteria A EN 61000 4 4 EFT Level 3 Criteria A EN 61000 4 5 Surge Level 3 Criteria B EN 61000 4 6 CS Level 3 Criteria A EN 61000 4 8 PFMF Magnetic Field...

Страница 5: ...king data traffic present UTP GREEN Off 10M 100M On 1000M on RJ45 port UTP YELLOW Off No link On UTP link OK Blinking data traffic present SYS Off Switch failed On Switch operating normally Note Gigab...

Страница 6: ...d PWR2 Observe voltage polarity when wiring power to the screw block connector Complete wiring without hot wires and with screw block connector disconnected from switch Installation Warning Ensure pro...

Страница 7: ...nit If wall mounting is needed first remove the DIN rail bracket If DIN rail bracket needs to be reattached make sure the spring is located on top position when unit is vertical Step 1 Step 2 Hold uni...

Страница 8: ...1 Use only indoors in climate controlled environments 2 Avoid looking directly into fibers or lasers while unit is powered 3 9 52V DC wide power input 48 52V DC for PoE PSE models not included FCC and...

Отзывы: