P2268BA-EN_b.fm, 08.02.2016
P2268BA/EN 2015-10
7
Before initial operation
3.2
Identifying and programming Arcnet address
Each socket tray is supplied with a default address (110) which can be seen on the respective type plate. If
only one socket tray is used, the default address is sufficient.
The default address must be changed if several
Arcnet components are connected to the system
bus. Identical addresses are not allowed.
Open the housing with a Phillips screwdriver and
continue with the next step.
Set the corresponding Arcnet address. Possible
address range 100–131.
The illustration on the right shows the default
address 110, where the two dials stand for the last
two digits. The first digit is always 1.
•
1
Fixed
•
1
HIGH switch for tens digit (00-30)
•
0
LOW switch for ones digit (0-9)
Note the new address.