Use case 1 – Controlling App/LG by socket removal
Fig. 4-3 System bus
Back with
<Navigator>.
Select <Navigator> <Advanced>
Controller Settings
.
Activate
Display mPro button
.
Save settings with <Navigator>.
Select <mPro>.
Select <Main menu> <System Programming>
Service > Programmable I/O mapping
.
Select User number
Service
(if required).
Enter password
0736381254
(if required).
Note warning. Select <Run>.
Fastenings must be completed or else the programmable I/O mapping will be disabled.
4.4
Defining input/output signals
Select signals individually and confirm with <Insert>
In dropdown list
1
, select
Group
(Tool).
In dropdown list
2
, select A-IOS (Arcnet bridge).
In input field
3
, enter Arcnet address, e.g. 110.
In dropdown list
4
, select the relevant inputs and outputs (see table).
In input field
5
, enter the relevant bit (see table).
4x socket tray
8x socket tray
Inputs
Bit
Outputs
Bit
Inputs
Bit
Outputs
Bit
Ext.App.Sel.1
Ext.App.Sel.2
Ext.App.Sel.3
Ext.App.Sel.4
0
1
2
3
Conf.App.Sel.1
Conf.App.Sel.2
Conf.App.Sel.3
Conf.App.Sel.4
8
9
10
11
Ext.App.Sel.1
Ext.App.Sel.2
Ext.App.Sel.3
Ext.App.Sel.4
Ext.App.Sel.5
Ext.App.Sel.6
Ext.App.Sel.7
Ext.App.Sel.8
0
1
2
3
4
5
6
7
Conf.App.Sel.1
Conf.App.Sel.2
Conf.App.Sel.3
Conf.App.Sel.4
Conf.App.Sel.5
Conf.App.Sel.6
Conf.App.Sel.7
Conf.App.Sel.8
8
9
10
11
12
13
14
15
c012
78en
.pn
g