12
P2300HW | 2019-03
Apex Tool Group
1
EN
I
nputs
•
External 24 V power supply for the controller.
•
Pin 11 and 23 (common GND) serve as a "return line"
for the outputs.
•
The GND for the external 24 V power supply must be
used as the return line for Pin 11 and 23.
Outputs
•
External 24 V power supply for the controller.
•
Pin 2 and 14 (common output) are the voltage source
for the inputs.
•
Pin 2 and 14 must be connected to the external 24 V
power supply.
Connectors – external power supply
Signal X9
Signal X10
Pin
I/O
Name
Pin
I/O
Name
12
Off
GND Int.
24
Off
GND Int.
11
On
GND I/O
23
On
GND I/O
10
Output
O3
22
Output
O3
9
Output
O2
21
Output
O2
8
Output
O1
20
Output
O1
7
Output
O0 (linking OK), e.g.
19
Output
O0 (linking OK), e.g.
6
Input
I3 (tool start), e.g.
18
Input
I3 (tool start), e.g.
5
Input
I2
17
Input
I2
4
Input
I1
16
Input
I1
3
Input
I0
15
Input
I0
2
On
+24 V O
14
On
+24 V O
1
Off
+24 V Int.
13
Off
+24 V Int.
+ -