X9, X10 – Input/Output
The required signal circuits are connected to these input/
output connectors. The signal groups are not galvanically
connected to the power supply; galvanic isolation is
required.
•
16 digital inputs/outputs, optically isolated for 24 V
level/0.5 A
•
8 inputs/8 outputs/2 +24 VDC/2 GND
•
Output current: 500 mA per output, 2000 mA total
Inputs
•
Internal 24 V power supply for the controller.
•
Pin 11 and 23 (common GND) serve as a "return line"
for the outputs.
•
Pin 11 and 23 must be connected to Pin 12 or 24 with
jumpers.
Outputs
•
Internal 24 V power supply for the controller
•
Pin 2 and 14 (common output) are the voltage source
for the inputs.
•
Pin 2 and 14 must be connected to Pin 1 or 13.
Note
A single device must not require a current of
more than 500 mA. The current monitor
switches off the output in the event of an
overcurrent.
2x12 pin Phoenix MCD 0.5/24-G1-2.5
Order No. S981211
Mating connector
Phoenix FK-MC 0.5/12-STZ3-2.5
Order No. S981211
X9
X10
Connectors – Internal power supply
Signal X9
Signal X10
Pin
I/O
Name
Pin
I/O
Name
12
Off
GND Int.
24
Off
GND Int.
11
On
GND I/O
23
On
GND I/O
10
Output
O3
22
Output
O7
9
Output
O2
21
Output
O6
8
Output
O1
20
Output
O5
7
Output
O0 (linking OK), e.g.
19
Output
O4
6
Input
I3 (tool start), e.g.
18
Input
I7
5
Input
I2
17
Input
I6
4
Input
I1
16
Input
I5
3
Input
I0
15
Input
I4
2
On
+24 V O
14
On
+24 V O
1
Off
+24 V Int.
13
Off
+24 V Int.
Содержание mPro400GCD-P
Страница 14: ...14 P2300HW 2019 03 Apex Tool Group 1 EN...
Страница 24: ...24 P2300HW 2019 03 Apex Tool Group 2 DE...
Страница 34: ...34 P2300HW 2019 03 Apex Tool Group 3 ES...
Страница 47: ......