Cleco LiveWire 943610PT Скачать руководство пользователя страница 13

Apex Tool Group

P2332BA | 2019-08

13

5
EN

5.4 Updating the firmware

Update the firmware using the 

LiveWire RF Settings

 pro-

gram. 
1. Select the 

Tool Identification

 tab. 

2. Press <Update Info> to check whether a correct con-

nection is possible. 

3. To select suitable software, press <Software Update>.

Make sure that firmware suitable for the socket tray is 
selected. This has the ending 

.tma

 and the name 

starts with 

S169280

.

4. Confirm the update process.

→ During the firmware update, the red and green LED 

display on the socket tray flashes and 

Softw 

update

 appears on the LCD. 

Fig. 5-5: Tool identification tab — software update

Once the update is complete, 

Update OFF

 appears on the 

LCD and the socket tray is automatically switched off.

The firmware is only temporarily stored during the down-
load. The boot loader does not therefore flash-save the 
firmware until the next time the socket tray is switched on. 
For this reason, the switch-on process takes a little longer 
(about five seconds) the first time it is switched on after the 
firmware download.

When the firmware has been flash-stored, the red and 
green LED display flash.

After flash-storing, the boot loader automatically starts the 
firmware and the normal starting procedure takes place.

5.5 Connecting to a nutrunner control 

system

The nutrunner control allows the connection to the socket 
tray. The corresponding steps are described in the pro-
gramming manual of the respective software.

If a connection is set up after switching on, the socket tray 
will expect a connection to be regularly set up by the nut-
runner control.

The LEDs indicate whether the socket tray is connected to 
the nutrunner control:

Green LED display lit up: Connection set up.

Red status LEDs on the inserts for the sockets flash-
ing: No connection could be set up within a pro-
grammed time. 

Conn. lost

 appears on the LCD. To fix 

the connection problem see chapter 

8 Troubleshoot-

ing, Seite 19

.

If a connection is interrupted and set up again, the pre-
vious status of the status LEDs on the inserts of the 
sockets is restored and 

Conn. set up

 is displayed on 

the LCD.

Содержание LiveWire 943610PT

Страница 1: ...For additional product information visit our website at www ClecoTools com Instruction Manual P2332BA 2019 08 943620PT 943610PT WLAN socket tray...

Страница 2: ...able language or transmitted on electronic mechanical optical or other media without the express permission of the Apex Tool Group Disclaimer Apex Tool Group reserves the right to modify supplement or...

Страница 3: ...ation 10 4 3 Charge battery pack 10 4 4 Installation 10 5 Commissioning 11 5 1 Opening the housing 11 5 2 Configuring the socket tray 11 5 2 1 Installing the USB interface driver 11 5 2 2 Installing t...

Страница 4: ...4 P2332BA 2019 08 Apex Tool Group EN 8 Troubleshooting 19 9 Technical Specifications 21 9 1 General Information 21 9 2 Mechanic dimensions and weights 21 10 Service 21 11 Disposal 21...

Страница 5: ...operation of this equip ment Other documents Symbols in the text Number Type P1970E Operating Manual Battery Pack 935377 P2372JH EC Declaration of Conformity P3315C Installation instructions S168688 L...

Страница 6: ...a hammer impact tool with outside control or battery Only use Apex Tool Group battery charger 24 V 935391 for charging Power supply Operation with 26 V battery pack 935377 a 44 V battery pack 936400PT...

Страница 7: ...he control and function elements Fig 3 2 External control and function elements Fig 3 3 Internal control and function elements Features 943620PT 943610PT Number of inserts 4 8 Select App 1 to 4 1 to 8...

Страница 8: ...The MAC address is defined by Cleco Production Tools and cannot be changed The other data can be changed with LiveWire RF Configuration software via USB connection to the PC 3 3 7 Wireless module The...

Страница 9: ...10PT 1 Pos 17 page 7 0 2 Pos 18 page 7 1 Component Battery pack li ion 26 V Order No 935377 Battery pack li ion 44 V Order No 936400PT Power Module PM48 Order No 961350PT LiveWire Memory Chip LMC Orde...

Страница 10: ...Inserts 4 3 Charge battery pack The battery pack is only partly charged upon delivery Fully charge the battery before using it for the first time See battery pack instruction manual P1970E 4 4 Install...

Страница 11: ...nternal control and function elements Seite 7 position 14 3 Switch on the socket tray 4 Plug the USB connector cable into the mini USB socket on the controller board and connect it to the PC 5 A suita...

Страница 12: ...ace port selected when the USB driver was installed This inter face port can be viewed in the Windows Device Man ager Fig 5 2 Properties of USB serial port COM4 2 Settings for the following can be mad...

Страница 13: ...a little longer about five seconds the first time it is switched on after the firmware download When the firmware has been flash stored the red and green LED display flash After flash storing the boot...

Страница 14: ...ate Status If the system is in the main menu or the submenus press and hold the function key F1 for two seconds to exit the menu level To switch the socket tray off press the on off switch and hold it...

Страница 15: ...evaluates the status of the initiators Connection lost A connection to a nutrunner control exists However the nutrunner control has not commu nicated with the socket tray again within the pro grammed...

Страница 16: ...unctions for the socket tray Administration Displays general points such as serial number software version LMC Shows the LiveWire Memory Chip set tings Wireless transmission Shows settings of wireless...

Страница 17: ...oards MAC address MAC address display Serial number Serial number display Country code Various WLAN frequency ranges are available World worldwide approved US CA approved in the USA EU approved in Eur...

Страница 18: ...of access point Transmission output Transmission output display Channel used Display of channel currently used Channels scanned Display of channels scanned UDP TCP communication protocol Selection of...

Страница 19: ...uration of the expansion board s incorrect Contact Sales Service Centers of the Apex Tool Group LMC is not readable Change LMC LMC is not available Insert LMC Initialization of the WLAN module failed...

Страница 20: ...tings submenu Port 4001 is disabled by a firewall Configure the firewall such that the required IP MAC addresses can use port 4001 The wireless channel at the access point is out side the range suppor...

Страница 21: ...ditions Storage temperature 25 C to 70 C Remove the battery to store the socket tray Ambient temperature 0 C to 45 C Permissible relative humidity 0 90 without condensa tion Electrical specifications...

Страница 22: ...x Tool Group GmbH C O Spline Gauges Piccadilly Tamworth Staffordshire B78 2ER United Kingdom Phone 44 1827 8727 71 Fax 44 1827 8741 28 FRANCE Apex Tool Group SAS 25 Avenue Maurice Chevalier ZI 77330 O...

Отзывы: