Apex Tool Group
P2332BA | 2019-08
19
8
EN
8
Troubleshooting
Problem
Possible cause
Measure
General socket tray
Socket tray indicates ini-
tialization error, see
6.3 Initialization error,
Seite 14.
Expansion board(s) not
inserted correctly.
Check plug connection.
Expansion board(s) not
set correctl.
Check the setting of the channel selector switch on the
expansion board:
-
The boards must be numbered from 0 to the number
-1 of the boards.
-
Each number may only be assigned once.
Expansion board(s)
defective.
Contact Sales & Service Centers of the Apex Tool Group.
Configuration of the
expansion board(s)
incorrect.
Contact Sales & Service Centers of the Apex Tool Group.
LMC is not readable.
Change LMC.
LMC is not available.
Insert LMC.
Initialization of the WLAN
module failed.
Contact Sales & Service Centers of the Apex Tool Group.
Idle speed not reached.
Battery voltage is too low.
Use fully charged battery.
Expected number of test
rundowns is not achieved
with one charge of the
battery.
Battery is not fully
charged.
Use fully charged battery.
The warning threshold for
undervoltage is not set to
minimum value.
On the control screen
Navigator > Tool Setup > Tool Set-
tings
, reduce the
Undervoltage (V)
.
The smallest possible value is 19 V.
Battery has too many
charging cycles.
After 800 charging cycles the capacity is reduced to approx.
60 %.