Page 16
PL12-1013EN
10/16/2014
Cleco
®
Maintenance
8 Maintenance
---------------------------------------------------------------------------------------------------------------------------------------
Danger of injury from accidental start up.
Turn off the compressed air before performing any maintenance.
---------------------------------------------------------------------------------------------------------------------------------------
8.1
Service schedule
Only qualified and trained personnel are permitted to perform maintenance on these tools.
Regular maintenance reduces operating faults, repair costs and downtime. In addition to the following
service schedule, implement a safetu related maintenance program that takes the local regulations for
repair and maintenance for all operating phases of the tool into account.
This maintenance schedule uses values that are valid for most applications. For a specific maintenance
interval, refer to 8.1.1 Calculating a customer-specific maintenance plan.
Maintenance
Interval
Rundowns
Daily
Daily
Ú
Ú
Ú
Ú
Visual inspection of air supply hose and connections
Inspect airline filter, regulator and lubricator for proper operation
Check the tool excessive vibration or unusual noises
Visual inspection of all external components of the tool
W1
100,000
Ú
Ú
Ú
Ú
Inspect the air hose for damage or wear
inspect the square drive output spindle for damage or wear
Inspect the air inlet adapter for a secure fit
Check the maximum free speed
W2
500,000
Ú
Ú
Ú
Check individual parts and replace if necessary
Replace O-rings and seals
Clean bronze mufflers
W3
1,000,000
Ú
Ú
Ú
Ú
Ú
Check individual parts and replace if necessary
Throttle valve
Motor
Gearing
Clutch
Designation
Содержание 19BPA
Страница 26: ...Page 26 PL12 1013EN 10 16 2014 Cleco Spare Parts 6 2 8 1 4 5 6 4 7 3 10 4 Motor Assembly...
Страница 42: ......