![Clearwater Enviro Technologies AG-150 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/clearwater-enviro-technologies/ag-150/ag-150_installation-and-operation-manual_2621981007.webp)
First layer
wrapping direction
Second layer wrapping direction
(same as the first)
Page 7
UNIT TYPE
Pipe Type
Pipe Size
Type of Coil
Wire Gauge Wraps
AG-150
Copper Pipe
.75"
Double*
18
50*
wraps x 2
AG-150
Copper Pipe
1"
Double*
18
45*
wraps x 2
AG-150
Copper Pipe
1.25"
Double*
18
40*
wraps x 2
AG-150
Copper Pipe
1.5"
Double*
18
35*
wraps x 2
AG-150
PVC/CPVC/PEX
.75"
Double*
18
70*
wraps x 2
AG-150
PVC/CPVC/PEX
1"
Single
18
57
AG-150
PVC/CPVC/PEX
1.25"
Single
18
50
AG-150
PVC/CPVC/PEX
1.5"
Single
18
34
AG-200
Copper Pipe
2"
Double*
12
68*
wraps x 2
AG-200
PVC/CPVC/PEX
2"
Single
12
82
AG-200
Ferrous Pipe
Call
Call
12
Call
AG-300
Copper Pipe
2.5"
Double*
12
64*
wraps x 2
AG-300
Copper Pipe
3"
Double*
12
60*
wraps x 2
AG-300
PVC/CPVC/PEX
2.5"
Single
12
71
AG-300
PVC/CPVC/PEX
3"
Single
12
61
AG-300
Ferrous Pipe
Call
Call
12
Call
AG-400
Copper Pipe
3.5"
Double*
12
58*
wraps x 2
AG-400
Copper Pipe
4"
Double*
12
56*
wraps x 2
AG-400
PVC/CPVC/PEX
3.5"
Single
12
52
AG-400
PVC/CPVC/PEX
4"
Single
12
40
AG-400
Ferrous Pipe
Call
Call
12
Call
E.) Installing the Signal Cable
(continued)
IT IS IMPERATIVE TO WRAP THE COIL THE CORRECT NUMBER OF TIMES.
PLEASE SEE CHART BELOW FOR CORRECT NUMBER OF WRAPS.
JUST BECAUSE YOU HAVE EXTRA WIRE DOES NOT MEAN YOU HAVE TO USE IT! DO NOT OVER WRAP THE COILS
MORE THAN THE RECOMMENDED NUMBER. DO NOT UNDER WRAP THE AMOUNT OF COILS SUGGESTED. Over
wrapping can significantly decrease the power of the signal. If you are unable to obtain correct number of wraps due to straight
pipe issues of not giving you enough space, the minimum number of wraps the unit requires is at least 30 wraps.
MAKE SURE THE WRAPS ARE FLUSH AGAINST ONE ANOTHER – NEVER OVERLAPPING. THIS IS EXTREMELY
IMPORTANT.
AS PREVIOUSLY NOTED, MAKE SURE THE CONTROL BOX IS MOUNTED AS CLOSE AS POSSIBLE TO WHERE THE SIGNAL
CABLE IS WRAPPED ON THE PIPE. THE MAXIMUM DISTANCE SHOULD NOT BE MORE THAN 10 FEET.
Double Wrap
Single Wrap
to power
box terminal
Straight section of pipe away
from angles, tees, valves and couplings
Balance of ScaleBlaster
signal cable
Cable Tie
1.
to power
box terminal
Cable Tie
Cable Tie
See wrap
maximum
chart
2.
3.
YOU MUST KEEP THE SECOND LAYER WRAPPING IN THE SAME DIRECTION AS THE FIRST!
Wrap right over the top of the first layer continuing in the same wrapping direction as the first layer – clockwise or
counterclockwise. This second and/or third layer must also be tight and touching the prior wrap.
*Example -
Double 80
wraps is a total
of 160 wraps.
80 wraps on
first layer and
80 on second
layer
continuing in the same direction
wrapping around the pipe as the first layer
4.