First layer 
wrapping direction

Second layer wrapping direction 

(same as the first)

Page 7

UNIT TYPE 

Pipe Type   

Pipe Size   

Type of Coil   

Wire Gauge    Wraps

AG-150   

Copper Pipe 

.75" 

 

Double* 

 

18 

  50* 

wraps x 2

AG-150   

Copper Pipe 

1" 

 

Double* 

 

18 

  45* 

wraps x 2

AG-150   

Copper Pipe 

1.25" 

 

Double* 

 

18 

  40* 

wraps x 2

AG-150   

Copper Pipe 

1.5" 

 

Double* 

 

18 

  35* 

wraps x 2

AG-150   

PVC/CPVC/PEX 

.75" 

 

Double* 

 

18 

  70* 

wraps x 2

AG-150   

PVC/CPVC/PEX 

1" 

 

Single 

 

18 

  57

AG-150   

PVC/CPVC/PEX 

1.25" 

 

Single 

 

18 

  50

AG-150   

PVC/CPVC/PEX 

1.5" 

 

Single 

 

18 

  34

AG-200   

Copper Pipe 

2" 

 

Double* 

 

12 

  68* 

wraps x 2

AG-200   

PVC/CPVC/PEX 

2" 

 

Single 

 

12 

  82

AG-200   

Ferrous Pipe 

Call 

 

Call 

 

12 

  Call

AG-300   

Copper Pipe 

2.5" 

 

Double* 

 

12 

  64* 

wraps x 2

AG-300   

Copper Pipe 

3" 

 

Double* 

 

12 

  60* 

wraps x 2

AG-300   

PVC/CPVC/PEX 

2.5" 

 

Single 

 

12 

  71

AG-300   

PVC/CPVC/PEX 

3" 

 

Single 

 

12 

  61

AG-300   

Ferrous Pipe 

Call 

 

Call 

 

12 

  Call

AG-400   

Copper Pipe 

3.5" 

 

Double* 

 

12 

  58* 

wraps x 2

AG-400   

Copper Pipe 

4" 

 

Double* 

 

12 

  56* 

wraps x 2

AG-400   

PVC/CPVC/PEX 

3.5" 

 

Single 

 

12 

  52

AG-400   

PVC/CPVC/PEX 

4" 

 

Single 

 

12 

  40

AG-400   

Ferrous Pipe 

Call 

 

Call 

 

12 

  Call

E.) Installing the Signal Cable 

(continued)

IT IS IMPERATIVE TO WRAP THE COIL THE CORRECT NUMBER OF TIMES.  

PLEASE SEE CHART BELOW FOR CORRECT NUMBER OF WRAPS.

JUST BECAUSE YOU HAVE EXTRA WIRE DOES NOT MEAN YOU HAVE TO USE IT!   DO NOT OVER WRAP THE COILS 
MORE THAN THE RECOMMENDED NUMBER.  DO NOT UNDER WRAP THE AMOUNT OF COILS SUGGESTED.  Over 
wrapping can significantly decrease the power of the signal.  If you are unable to obtain correct number of  wraps due to straight 
pipe issues of not giving you enough space, the minimum number of wraps the unit requires is at least 30 wraps. 

MAKE SURE THE WRAPS ARE FLUSH AGAINST ONE ANOTHER – NEVER OVERLAPPING. THIS IS EXTREMELY 

IMPORTANT.

AS PREVIOUSLY NOTED, MAKE SURE THE CONTROL BOX IS MOUNTED AS CLOSE AS POSSIBLE TO WHERE THE SIGNAL 

CABLE IS WRAPPED ON THE PIPE.  THE MAXIMUM DISTANCE SHOULD NOT BE MORE THAN 10 FEET.  

Double Wrap

Single Wrap

to power

box terminal

Straight section of pipe away 

from angles, tees, valves and couplings

Balance of ScaleBlaster 
signal cable

Cable Tie

1.

to power

box terminal

Cable Tie

Cable Tie

See wrap

maximum

chart

2.

3.

YOU MUST KEEP THE SECOND LAYER WRAPPING IN THE SAME DIRECTION AS THE FIRST!  

Wrap right over the top of the first layer continuing in the same wrapping direction as the first layer – clockwise or 

counterclockwise.  This second and/or third layer must also be tight and touching the prior wrap.

*Example - 

Double 80 

wraps is a total 

of 160 wraps. 

80 wraps on 

first layer and 

80 on second 

layer

continuing in the same direction 
wrapping around the pipe as the first layer

4.

Содержание AG-150

Страница 1: ... Control System 115 230 VAC Auto Selected AG 300 for pipe sizes up to 3 non ferrous AG 400 for pipe sizes up to 4 non ferrous AG 150 for pipe sizes up to 1 non ferrous AG 200 for pipe sizes up to 2 non ferrous 12 16 Electronic Lime Scale Control System for Agriculture Applications ...

Страница 2: ...ron theoutsideof theshippingbox If the malfunction or failure is a result of defects covered by this warranty ClearwaterEnviroTech will repair the product or replace it andreturnittothepurchaser Afteraperiodoffiveyears asmalllaborandpartschargewilloccur This warranty is limited to the original retail purchaser and is not transferable This warranty does not cover damage due to accidents abuse tampe...

Страница 3: ...AG 200 AG 300 AG 400 signal wire length to be determined by specific application pipe size and pipe material 3 Long nylon cable ties 5 or 3 5 for the AG 150 or 3 for the AG 200 AG 300 AG 400 These ties aid in securing the cable to the pipe 4 Warranty Card along with this Installation Operations Manual 5 Shipping Box Please save the foam inserts and shipping box it is made to protect the descaler d...

Страница 4: ...near an electrical outlet This signal cable must be within 10 feet of the control box no matter what At least 6 of straight pipe before and after coil Wrap coil tightly See chart for number of wraps At least 6 of straight pipe before and after coil Tie wrap Tie wrap Power cable is 5 long If required use a 16 awg extension cord of no more than 25 Power source 115VAC or 230VAC unit auto switches Coi...

Страница 5: ...ors or outdoors as the unit is in a weatherproof UL CUL and CE listed enclosure If outdoors make sure the install area is out of direct sunlight In extremely hot or cold areas of the world it may be best to enclose our power box computer in another box to protect the LCD window and other inside components The power unit should be mounted on a wall or solid surface within 5 feet from an electrical ...

Страница 6: ...s of the signal cable Tighten the bare wires together to get rid of any stray strands 2 Unscrew one of the two receptacle posts located on the ScaleBlaster power box computer It does not matter if you use the red or black receptacle first 3 Then insert the spliced wire of the signal cable end completely through the opening Tighten the receptacle post as much as possible 4 It is very important you ...

Страница 7: ...OU HAVE EXTRA WIRE DOES NOT MEAN YOU HAVE TO USE IT DO NOT OVER WRAP THE COILS MORE THAN THE RECOMMENDED NUMBER DO NOT UNDER WRAP THE AMOUNT OF COILS SUGGESTED Over wrapping can significantly decrease the power of the signal If you are unable to obtain correct number of wraps due to straight pipe issues of not giving you enough space the minimum number of wraps the unit requires is at least 30 wra...

Страница 8: ...just isn t yet attached the screen to the left will appear If the coil is connected and the message to the left is present then contact your dealer or Clearwater Enviro Tech for help AG 300 AG 400 This screen to the right will appear if the internal temperature reaches 180 degrees Fahrenheit At this point the unit will shut down until the temperature subsides This can happen if you inadvertently s...

Отзывы: