Clearwater Enviro Technologies AG-150 Скачать руководство пользователя страница 6

D.) Mounting the Power Box

E.) Installing the Signal Cable

Page 6

Mount the power box / computer to the wall after drilling the four holes in the determined location.  Use the appropriate screws and anchors (if needed) 
depending on the surface (wood, stucco, etc.). 

 This should be within 5 ½ feet of a power source and 10 feet of the location for the signal cable.  

If 

this is not possible, you may add an extension cord to the 115 VAC plug at the end of the power cord.

The unit can be installed indoors or outdoors as long as it is 

out of direct sunlight

.  The unit will work on either 115 VAC or 230 VAC with no 

adjustments.  You can either plug the unit in a 115 VAC power outlet, or wire it directly into a 230 VAC source by removing the power plug.  We 
strongly recommended a licensed electrician if wiring to 230 VAC.

AG-300

12.75" H

8.00" W

AG-400

14.75" H

10.00" W

Top and / or bottom of the power unit 

showing the mounting bracket (AG 200, 300 and 400).

Close up of mounting hole

®

1/4" Tapcon

1/4" Zinc Lag with 
                         Washer

This model is designed specifically for commercial use, and will not work on galvanized or magnetic pipe.   You may need to replace a small section of pipe where the 
signal cable is to be installed if it is a ferrous based pipe.  You can replace it with copper or pvc pipe.  There is no need to replace the galvanized pipe downstream, as 
the 

ScaleBlaster

 will descale the pipes from that point forward (from the location of where the signal cable is wrapped).

This unit is equipped with a roll of 18 or 12 awg signal cable.  The maximum pipe size the unit will work on is indicated in the chart on the next page.

1.)  Carefully strip off 2" (51mm) of the outer rubber shield from one of the ends of the signal cable.  Tighten the bare wires together to get rid of any stray strands.
2.)  Unscrew one of the two receptacle posts located on the 

ScaleBlaster

 power box / computer.  It does not matter if you use the red or black receptacle first.  

3.)  Then insert the spliced wire of the signal cable end completely through the opening.  Tighten the receptacle post as much as possible.
4.)  It is very important you have a tight connection and that all wire threads go through the opening in the receptacle.
5.)  Route the signal cable from the control box to the inlet pipe. Hold the cable parallel and against the pipe and then secure the cable to the pipe with one of the nylon 

cables ties.  Make sure the tie is pulled tightly so that the cable is well attached to the pipe.  Remove excess cable tie with scissors.

6.)  Using finger pressure to keep the signal cable and tie from moving, begin wrapping the signal cable securely around the pipe in any direction around the pipe.  The 

correct number of wraps depends on pipe size and composition.

7.)  Once the wrapping is complete, secure the signal cable to the pipe, using another enclosed cable tie.  Remove the excess cable tie with scissors or cutters.
8.)  Route the loose end of the signal cable back to the control box.  Trim the cable wire to length, getting rid of any excess wire.  You want to get the wire from the 

pipe to the power box / computer as taut as possible.

DO NOT ALLOW THE WIRES GOING TO THE CONTROL BOX - TO AND FROM THE WRAPPED COIL - TO OVERLAP OR TOUCH EACH OTHER

9.)  Carefully strip the outer plastic shield from the other end of the signal cable, leaving about two inches of bare cable.  Twist the bare cable and insert the end into 

the unused receptacle post (either red or black).  Tighten the receptacle post.  Again, make sure all threads have passed through the opening for a 100% connection.

AG-200

8.50" H

13.00" W

13.00"

(30.02cm)

8.50"

(21.59cm)

Содержание AG-150

Страница 1: ... Control System 115 230 VAC Auto Selected AG 300 for pipe sizes up to 3 non ferrous AG 400 for pipe sizes up to 4 non ferrous AG 150 for pipe sizes up to 1 non ferrous AG 200 for pipe sizes up to 2 non ferrous 12 16 Electronic Lime Scale Control System for Agriculture Applications ...

Страница 2: ...ron theoutsideof theshippingbox If the malfunction or failure is a result of defects covered by this warranty ClearwaterEnviroTech will repair the product or replace it andreturnittothepurchaser Afteraperiodoffiveyears asmalllaborandpartschargewilloccur This warranty is limited to the original retail purchaser and is not transferable This warranty does not cover damage due to accidents abuse tampe...

Страница 3: ...AG 200 AG 300 AG 400 signal wire length to be determined by specific application pipe size and pipe material 3 Long nylon cable ties 5 or 3 5 for the AG 150 or 3 for the AG 200 AG 300 AG 400 These ties aid in securing the cable to the pipe 4 Warranty Card along with this Installation Operations Manual 5 Shipping Box Please save the foam inserts and shipping box it is made to protect the descaler d...

Страница 4: ...near an electrical outlet This signal cable must be within 10 feet of the control box no matter what At least 6 of straight pipe before and after coil Wrap coil tightly See chart for number of wraps At least 6 of straight pipe before and after coil Tie wrap Tie wrap Power cable is 5 long If required use a 16 awg extension cord of no more than 25 Power source 115VAC or 230VAC unit auto switches Coi...

Страница 5: ...ors or outdoors as the unit is in a weatherproof UL CUL and CE listed enclosure If outdoors make sure the install area is out of direct sunlight In extremely hot or cold areas of the world it may be best to enclose our power box computer in another box to protect the LCD window and other inside components The power unit should be mounted on a wall or solid surface within 5 feet from an electrical ...

Страница 6: ...s of the signal cable Tighten the bare wires together to get rid of any stray strands 2 Unscrew one of the two receptacle posts located on the ScaleBlaster power box computer It does not matter if you use the red or black receptacle first 3 Then insert the spliced wire of the signal cable end completely through the opening Tighten the receptacle post as much as possible 4 It is very important you ...

Страница 7: ...OU HAVE EXTRA WIRE DOES NOT MEAN YOU HAVE TO USE IT DO NOT OVER WRAP THE COILS MORE THAN THE RECOMMENDED NUMBER DO NOT UNDER WRAP THE AMOUNT OF COILS SUGGESTED Over wrapping can significantly decrease the power of the signal If you are unable to obtain correct number of wraps due to straight pipe issues of not giving you enough space the minimum number of wraps the unit requires is at least 30 wra...

Страница 8: ...just isn t yet attached the screen to the left will appear If the coil is connected and the message to the left is present then contact your dealer or Clearwater Enviro Tech for help AG 300 AG 400 This screen to the right will appear if the internal temperature reaches 180 degrees Fahrenheit At this point the unit will shut down until the temperature subsides This can happen if you inadvertently s...