39
CLEARSPAN
™
POLY BUILDINGS
Revision date: 05.20.20
22
INSTALL GATHERING DOOR FLAT PLATES
Before cutting the door opening in the end panel,
secure the flat plates along each door jamb.
These provide a mounting surface for additional
gathering door hardware. Plates run from ground
level up to the header along each side of the door
opening. They also help to secure the end panel
to the end wall frame. Required parts include:
• 106937 16 gauge galvanized flat plates
• FAJ117B (5/16" x 3") lag bolts
Install flat
plates here
Complete these steps to attach the flat plates to the door jambs.
1. Take one section of the 106937 flat plate material and pre-drill the 5/16" mounting holes. Measure 1" in
from one long edge and mark hole locations at approximately 24" on-center throughout the length. Set
the first hole 1" in from the end. Repeat this for the remaining 106937 plates.
2. Beginning at ground level, place the first section of 106937 (6" x 10') against the 6" x 6" door jamb
flush
with the inside edge
and secure to the jamb using FAJ117B (5/16" x 3") lag bolts. See diagram below.
3. Cut a section of 106937 material to finish the area above the first plate and secure that to the jamb.
4. Repeat the steps to attach the plates to the remaining jamb and to the jambs at the other end of the
building.
5. Continue by removing the end panel material from within the door opening.
End Panel
Conduit
End Panel
Conduit
Install first 10'
section of 106937
in lower position.
Install 5' section of
106937 in upper
position.
Remove end panel material from
door opening after attaching the
flat plates to the door jambs.
106937 Plates