background image

CLEARSPAN

 COMMERCIAL CANOPIES

12

Revision date: 06.22.10

Using the main cover conduit and the straps as guides, 

13. 

attach the ratchets to the rafters at the proper height. 

Fasten ratchets to the outside of these rafters using a 

Tek screw for each ratchet.

Lift the cover skirt (if present) and cut a slit in the cover 

14. 

conduit pocket at the rafter position. Insert a 3' section 

of strap through the slit and around the cover conduit. 

 

NOTE: 

DO NOT cut through the main cover. 

Cut 

through the conduit pocket only.

Thread the strap ends into a ratchet and slightly 

15. 

tighten. 

 

NOTE:

 It may be necessary to remove excess strap if it 

binds up in the ratchet.
Repeat the steps for the remaining ratchets.

16. 

Using additional help (if needed) tighten the main cover 

17. 

beginning with the ratchets along the side of the shelter 

frame.
After the side ratchets are tightened, return to the end 

18. 

ratchets and tighten. 

 

NOTE:

 Loosen the ratchets if needed to remove 

excess strap and retighten. Loosen all ratchet if needed 

to reposition the main cover on the frame and retighten  

the ratchets.
Fold the skirt of main cover down and over the ratchets 

19. 

to complete the installation of the main cover.  

 

NOTE:

 Depending on the shelter, some main covers 

may not include a cover skirt.

INSTALL COVER (CONTINUED)

SHELTER CARE AND MAINTENANCE

Proper care and maintenance of your shelter is important. 

Check the following items periodically to properly maintain 

your shelter:

Regularly check the main cover and panels (if 

• 

equipped) to see that these remain tight and in proper 

repair.
Check connections and all fasteners to verify that they 

• 

remain tight.
Do not climb or stand on the shelter at anytime.

• 

Remove debris and objects that may accumulate on 

• 

the shelter. Use tools that will not damage the cover 

when removing debris.
Remove snow to prevent excess accumulation. Use 

• 

tools that will not damage the cover when removing 

snow.
Check the contents of the shelter to verify that  

• 

nothing is touching the cover or the side panels that 

could cause damage.
Check the anchoring system to ensure that all  

• 

components are tight and in good repair.
If the shelter is moved, inspect all parts and  

• 

connections before reassembling.
For replacement or missing parts, call 1-800-245-9881 

• 

for assistance.

NOTE:

 With the exception of Truss Arch buildings,  

ClearSpan™ shelters and greenhouses do not have any 

tested loading criteria.

Содержание 2420CC

Страница 1: ... ClearSpan All Rights Reserved Reproduction is prohibited without permission ClearSpan Commercial Canopies Photo may show a different but similar model STK DIMENSIONS 2420CC 24 W x 20 L 2430CC 24 W x 30 L 2440CC 24 W x 40 L 2450CC 24 W x 50 L 2460CC 24 W x 60 L ...

Страница 2: ...manufacturer s warranty and may cause serious injury and damage LOCATION Choosing the proper location is an important step before you begin to assemble the structure The following suggestions and precautions will help you determine whether your selected location is the best location Never erect the structure under power lines Identify whether underground cables and pipes are present before prepari...

Страница 3: ...o aid in the assembly read through the following definitions before you begin to assemble your shelter Conduit An assembly of pipes used to secure the main cover and end panels if equipped Purlins and some strut assemblies also consist of connected pipes to form a conduit Each pipe joint of a conduit assembly is secured with a self tapping Tek screw Coupler or Fitting A part of the frame assembly ...

Страница 4: ...Sheets Verify that all parts listed on the Bill of Materials Spec 2 Sheets are present If anything is missing or you have questions consult the Pictorial Parts Guide and all shelter diagrams for clarification or contact Customer Service NOTE At this time you do not need to open the plastic bags containing smaller parts such as fasteners or washers QUICK START GUIDE For an overview of this shelter ...

Страница 5: ...elp you identify the different parts and show you how they are used Not all parts are shown QH1061 Ratchet 103620b Plain End Strap Swaged Plain Swaged and Plain Rafter Sections not all pieces are shown FA4470B Tek screw 100442 Nut Setter 102193 3 Way Coupler 102194 4 Way Coupler QH1402 Band Clamp ...

Страница 6: ...ersonal injury and damage to the shelter fasten and tighten a Tek screw at each pipe and coupler joint To prevent cover damage install the Tek screw so that it does not touch the main cover or any optional side or end panels once these are installed 4 Way Coupler no lock bolt 4 Way Coupler includes lock bolt Additional Parts Identification Notes In some instances there can be differences between t...

Страница 7: ...2 10 NOTE Diagram above may show a shelter that differs in length or width from the actual frame Frame above is used for illustration purposes frame diagram Interior Rafter End Rafter Purlins Horizontal Strut ClearSpan WeatherShield Commercial Canopies ...

Страница 8: ...r application the footings and the method used to anchor the shelter Square the Site Identify a corner where a building rafter will be 1 positioned drive in a stake and string a line the exact width of the building and stake in place Sting a line at least as long as the building from the first 2 stake at 90 NOTE A transit can be used to ensure an accurate 90 angle or the 3 4 5 rule can be used Ref...

Страница 9: ...or all rafter assemblies FRAME TOP VIEW Examine the frame and remove any sharp edges from 3 the frame or reposition screws if equipped so they do not come in contact with the roof cover After the frame is squared read or reread the MUST 4 READ document and anchor the shelter FRAME ASSEMBLY CONTINUED Add horizontal struts QH1308 between rafter pipes 4 at each rafter Secure at each end using a band ...

Страница 10: ...r s warranty and may cause serious injury and damage Install all side panels and or end panels and continue 3 with the main cover WARNING Do not install panels without first anchoring the assembled frame Optional Side Panel INSTALL MAIN COVER Gather the parts Ratchets 1 4000lb Pipes 1 315 See chart below Cover Ropes long enough to reach over the frame supplied by customer Tek screws and duct tape ...

Страница 11: ...ch side of the shelter and directly across from each other on the same rafter assembly Rafters are identified by the arrows below NOTE Shelter shown above may differ in length from the actual model To pull the cover over the frame attach ropes to both 6 ends of the cover conduit Wrap the rope around the conduit a few times to prevent it from slipping off NOTE Depending on the length of the cover i...

Страница 12: ...of main cover down and over the ratchets 19 to complete the installation of the main cover NOTE Depending on the shelter some main covers may not include a cover skirt INSTALL COVER CONTINUED SHELTER CARE AND MAINTENANCE Proper care and maintenance of your shelter is important Check the following items periodically to properly maintain your shelter Regularly check the main cover and panels if equi...

Страница 13: ...S Revision date 06 22 10 Quick Start Guide 24 Wide Commercial Canopies Width 22 10 11 16 Height 13 1 15 16 6 5 Endwall Height Grid Represents 12 Squares FRONT 2460CC 24 x 60 2420CC 24 x 20 2430CC 24 x 30 2440CC 24 x 40 2450CC 24 x 50 ...

Страница 14: ... PROFILE End Rafters 102193 Mid Rafters 102194 End Rafters 102193 Mid Rafters 102194 End Rafters 102193 Mid Rafters 102194 166S099 1 66 pipe 99 166P058 1 66 pipe 58 166P077 1 66 pipe 77 166P077 1 66 pipe 77 166P058 1 66 pipe 58 166S099 1 66 pipe 99 QH1308 7 Strut ...

Страница 15: ...15 CLEARSPAN COMMERCIAL CANOPIES Revision date 06 22 10 SIDE PROFILE 2420CC 166P058 1 66 pipe 58 Rafter Spacing 5 0 20 0 Length Ratchets secured to rafters indicated with R R R ...

Страница 16: ...CLEARSPAN COMMERCIAL CANOPIES 16 Revision date 06 22 10 SIDE PROFILE 2430CC 166P058 1 66 pipe 58 Length 30 0 5 0 Rafter Spacing Ratchets secured to rafters indicated with R R R R ...

Страница 17: ...17 CLEARSPAN COMMERCIAL CANOPIES Revision date 06 22 10 SIDE PROFILE 2440CC 166P058 1 66 pipe 58 40 0 Length 5 0 Rafter Spacing Ratchets secured to rafters indicated with R R R R R ...

Страница 18: ...CLEARSPAN COMMERCIAL CANOPIES 18 Revision date 06 22 10 SIDE PROFILE 2450CC 166P058 1 66 pipe 58 50 0 Length 5 0 Rafter Spacing Ratchets secured to rafters indicated with R R R R R R ...

Страница 19: ...19 CLEARSPAN COMMERCIAL CANOPIES Revision date 06 22 10 SIDE PROFILE 2460CC 60 0 Length 5 0 Rafter Spacing Ratchets secured to rafters indicated with R R R R R R R ...

Страница 20: ...CLEARSPAN COMMERCIAL CANOPIES 20 Revision date 06 22 10 CONNECTIONS End Rafter Purlin Connection View 1 Mid Rafter Purlin Connection View 2 Rafter Chord Connection View 3 ...

Страница 21: ...06 22 10 CONNECTION DETAILS Rafter QH1402 1 66 Band Clamp QH1308 7 Chord 102194 4 Way Connector Rafter Purlin View 1 End Rafter Purlin Connection View 2 Mid Rafter Purlin Connection 102193 3 Way Connector Purlin Rafter View 3 Rafter Chord Connection ...

Отзывы: