background image

CLEARSPAN

 SUNBLOCKER SYSTEM

8

Visit 

www.ClearSpan.com

 for additional products and customer assistance. 

Revision date: 10.04.07

5-Way Coupler 

(#103839)

Cap Screws

(#FAG355)

Leg Pipe 

(Plain End)

RAFTER ASSEMBLY

The leg assemblies are connected with plain pipes to form 

the rafters.  

 

NOTE:

 The basic 10' x 20' shelter has no interior rafters; 

only the 10' x 40' and 10' x 60' shelters have interior rafters. 

 

Gather the parts:
•  Leg assemblies 
•  Plain pipe (#2375P120)
•  Cap screw 3/8'' x 1'' (#FAG355)
•  Strut (#103838) and band clamp (#103856)
1.  Select a plain 10' pipe and slide two (2) band 

clamps onto the pipe. This pipe connects two (2) leg 

assemblies.

2.  Slide each end of the plain pipe into the through ports 

of the 5-way couplers as shown below and align the 

pipe ends with the center of the 5-way coupler. 

NOTE:

 Position the 5-way couplers so the 

through tube

 

is aligned with the width of the frame

.

3.  Verify that the on-center width dimension measured at 

the 5-way couplers is 10'-2 3/4". Adjust as needed.

4.  Secure the plain pipe to the couplers using 3/8'' x 1'' 

cap screws through the threaded holes of each coupler. 

5.  Reposition the band clamps (previously installed on 

each rafter leg and the 10' rafter pipe) approximately 

12" from the 5-way couplers.  

 

NOTE:

 If the band clamps were not installed, install 

them now. Use adjustable pliers to squeeze the clamps 

back into shape after adding them to the pipes.

LEG ASSEMBLY

Each leg assembly consists of one (1) drilled pipe, one (1) 

5-way coupler, and required cap screws or bolts. 

 

Gather the parts:
•  Drilled leg pipe (#2375120D) and 5-way coupler 

(#103839)

•  Cap screw 3/8'' x 1'' (#FAG355B) and band clamp 

(#103856)

1.  Insert the plain end of a drilled pipe into the bottom 

(odd) port of a 5-way coupler.

2.  Secure the pipe in the 5-way coupler using 3/8'' x 1'' 

cap screws through the threaded holes of the coupler. 

NOTE:

 Install the drilled pipes with the plain end 

inserted into the 5-way coupler. The drilled end of the 

pipes are attached to ground posts or mounting feet if 

used. 

3.  Assemble the legs until all drilled pipes and 5-way 

couplers are used. 

4.  Slide a band clamp onto each leg assembly and 

position it near the 5-way coupler. Slightly tighten the 

band clamp or use tape to keep it in place. 

 

NOTE:

 If *mounting feet are used, attach a foot to each 

leg assembly using bolts and nuts at this time. 

 

If *ground posts are used, drive the post into the 

ground so the top of the post is 1' foot above the 

finished grade. Refer to the MUST READ document 

sent with the shelter. Use the Quick Start diagrams to 

properly space the ground posts if used. 

 

*Additional purchase required for mounting feet and 

ground posts.

10' Plain Pipe

Leg Assembly

Through Port

10'-2 3/4"  

on-center

Band Clamp

Rafter Assembly

Содержание 1020SS

Страница 1: ...mer assistance Revision date 10 04 07 ClearSpan Add A Bay Shade System STK DIMENSIONS 1020SS 10 W x 20 L x 10 H 1040SS 10 W x 40 L x 10 H 1060SS 10 W x 60 L x 10 H Photo may show a different but similar model 2007 ClearSpan All Rights Reserved Reproduction is prohibited without permission ...

Страница 2: ...y will void the manufacturer s warranty and may cause serious injury and damage LOCATION Choosing the proper location is an important step before you begin to assemble the structure The following suggestions and precautions will help you determine whether your selected location is the best location Never erect the structure under power lines Identify whether underground cables and pipes are presen...

Страница 3: ...pec sheets included with the shipment To aid in the assembly read through the following definitions before you begin to assemble your shelter Conduit An assembly of pipes used to secure the main cover and end panels if equipped Purlins and some strut assemblies also consist of connected pipes to form a conduit Each pipe joint of a conduit assembly is secured with a self tapping Tek screw Coupler o...

Страница 4: ...g designed to work safely at the height of the shelter UNPACK AND IDENTIFY PARTS The following steps will ensure that you have all the necessary parts before you begin to assemble the shelter Unpack the contents of the shipment and place where you can easily inventory the parts Refer to the Bill of Materials Spec Sheets Verify that all parts listed on the Bill of Materials Spec Sheets are present ...

Страница 5: ... QUICK START GUIDE The following graphics and photos will help you identify the different parts and show you how they are used Not all parts are shown 103856 Band Clamp 103838 Strut CC4595 Ball Tie Down 103837 Straight Coupler 2375P120 Plain Pipe 2375P120D Drilled Pipe 103839 5 Way Coupler Cross Port Cross Port Through Port ...

Страница 6: ...ion below helps identify the main parts of the shelter 1 Locate the required parts for each assembly procedure 2 Assemble the frame components 3 Assemble and anchor the frame 4 Prepare and install the cover Rafters ATTENTION Position screws so they will not touch the cover when it is installed IMPORTANT Cross ports of the 5 way coupler are divided by the through port of the same coupler There are ...

Страница 7: ...at follows ANCHOR THE FRAME Turnbuckles and ground anchors can be used to anchor this type of shelter Ground posts and mounting feet can also be used with the above items Consult a reliable construction professional if you need assistance when anchoring the assembled frame WARNING Securing the legs to concrete blocks or wood boards set on the site is not a substitute for properly anchoring the she...

Страница 8: ...were not installed install them now Use adjustable pliers to squeeze the clamps back into shape after adding them to the pipes LEG ASSEMBLY Each leg assembly consists of one 1 drilled pipe one 1 5 way coupler and required cap screws or bolts Gather the parts Drilled leg pipe 2375120D and 5 way coupler 103839 Cap screw 3 8 x 1 FAG355B and band clamp 103856 1 Insert the plain end of a drilled pipe i...

Страница 9: ...post NOTE Before securing the rafter legs to the ground posts if used refer to the diagram for your shelter in the Quick Start section to determine where to attach the diagonal struts Slide additional band clamps onto the legs of each rafter assembly as needed 2 Position a second rafter assembly as shown and brace or secure it in place at approximately 20 from the first rafter 5 Use the diagrams a...

Страница 10: ...ck Start section for your shelter to determine the locations of the remaining diagonal struts 7 Install the diagonal struts Each corner connection uses two 2 struts and each mid connections if present uses three 3 struts Refer to Quick Start Guide for location and additional details 8 With the struts in position tighten the band clamps 9 Once the frame assembly is complete verify that all frame bo...

Страница 11: ...drape it over the frame and into position 2 Take the snugger ball tie downs feed the stretch cord through a grommet and attach the main cover to the assembled frame Use one snugger ball for each grommet 3 Continue with the shelter care and maintenance information that follows A space will remain between the edge of the main cover and the frame See the inserts below and to the left NOTE Dashed line...

Страница 12: ...ter Use tools that will not damage the cover when removing debris Remove snow to prevent excess accumulation Use tools that will not damage the cover when removing snow Check the contents of the shelter to verify that nothing is touching the cover that could cause damage Check the anchoring system to ensure that all components are tight and in good repair If the shelter is moved inspect all parts ...

Страница 13: ...Span com for additional products and customer assistance Revision date 10 04 07 QUICK START GUIDE 10 Wide SunBlocker Shade System 10 2 3 4 Width 10 1 1 2 Height Grid Represents 12 Squares F FR RO ON NT T 1020SS 10 x 20 1040SS 10 x 40 1060SS 10 x 60 ...

Страница 14: ...CLEARSPAN SUNBLOCKER SYSTEM 14 Visit www ClearSpan com for additional products and customer assistance Revision date 10 04 07 FRONT PROFILE 2375P120D 103838 103856 103839 ...

Страница 15: ...15 CLEARSPAN SUNBLOCKER SYSTEM Visit www ClearSpan com for additional products and customer assistance Revision date 10 04 07 SIDE PROFILE 1020SS 103837 20 3 Length ...

Страница 16: ... Visit www ClearSpan com for additional products and customer assistance Revision date 10 04 07 103837 2375P120 20 3 Rafter Spacing 40 6 Length SIDE PROFILE 1040SS 103837 2375P120 20 3 Rafter Spacing 60 9 Length SIDE PROFILE 1060SS ...

Страница 17: ...l products and customer assistance Revision date 10 04 07 CONNECTIONS End Rafter Purlin Connection View 1 Mid Purlin Connection View 2 End Rafter Purlin Connection Mid Purlin Connection 103839 Rafter Purlin Purlin 103837 View 1 View 2 Cross Port Cross Port Through Port ...

Отзывы: