Appendices
~ Appendix E: Serial Commands
96
Technical Services Group
~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Meter type definitions
Serial command error codes
Error number
Text message
Explanation/Solution
1
Memory error
The box is out of internal memory. Power cycle the box.
2
No command found
A command was not found in the string.
3
Unknown command
A command was executed on a different device type that this box
response
cannot display. The command dictionary needs to be updated.
4
Not implemented
The command is not implemented.
5
Argument error
The command had an argument that was out of range.
6
Unknown command
The command is unknown to this unit.
7
Bad checksum
The binary command’s checksum is wrong.
8
Preset of macro invalid
A preset or macro failed to program because it is too large or
because its comand list contained an invalid command.
10
Queue error
The internal command queue is full. Enable flow control and use
all five pins on the serial port.
11
Command too big
The binary command is too large.
12
Unit is locked
Unlock the unit with the proper password.