28 Technical Services: 800-283-5936
MIN
– Minimum Gain Setting
This command changes or reports back the minimum gain setting for a channel.
Command Form
: DEVICE
MIN
<Channel> <Group> [Value]
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
Group
Group
1
1, 2, 3, 5, 7, 12, 16, 17 (I, O, M, P, L, F, T, R)
Value
Signed Float
2
-65.00 – 20.00
(Null to query in text)
dB
MINMAX
– Minimum and Maximum Gain Setting
This command changes or reports back the minimum and maximum gain setting for a channel.
Command Form
: DEVICE
MINMAX
<Channel> <Group> [Min Max]
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
Group
Group
1
1, 2, 3, 5, 7, 12, 16, 17 (I, O, M, P, L, F, T, R)
Min
Signed Float
2
-65.00 – 20.00
(Null to query in text)
dB
Max
Signed Float
4
-65.00 – 20.00
dB
MLINE
– Mic / Line Coarse Gain Setting
This command selects/reports the setting of coarse gain.
Command Form
: DEVICE
MLINE
<Channel> [Value]
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
Group
Group
1
3 (M)
Value
Unsigned Integer
2
0 = 0 dB
7 = 7 dB
14 = 14 dB
21 = 21 dB
28 = 28 dB
35 = 35 dB
41 = 41 dB
50 = 50 dB
56 = 56 dB
(Null to query in text)
(No other values are valid and accepted)
MMAX
– Maximum Number of Microphones
This command selects/reports the maximum number of microphones for a Gating Group.
Command Form
: DEVICE
MMAX
<Channel> [Value]
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
Group
Group
1
4 (G)
Value
Unsigned Integer
2
0 = Unlimited
1 - 8 = Maximum # of Mics
(Null to query in text)