16 Technical Services: 800-283-5936
DEVICETYPE
– Sets the Type of a Connected Device
This command enables / disables or reports the current type of device connected to an input or output.
Command Form
: DEVICE
DEVICETYPE
<Channel> <Group> [Value]
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
Group
Group
1
1, 2, 3, 7 (I, O, M, L)
Value
Unsigned Integer
2
(NULL to query in text)
DFLTM
– Default Meter
This command selects/reports the setting of the default meter on the front panel.
Command Form
: DEVICE
DFLTM
[Channel Group Position]
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
(Null to query in text)
Group
Group
1
1, 2, 3, 7, 16, 17 (I, O, M, L, T, R)
Position
Meter Type
2
1 – 4, as applicable for group
See
Meter Type Definitions
DIAL
– DTMF Dialing (840T & TH20 only)
This command dials a DTMF sequence or reports back the last sequence dialed.
Command Form
: DEVICE
DIAL
<Channel> [Number]
Argument
Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
Group
Group
1
17 (R)
Reserved
2
0
Number
String
40
1 – 40 Chars of ‘0’ – ‘9’, ‘A’ – ‘D’, ‘*’, ‘#’, ‘,’
(Null to query last number dialed in text)
DID
– Device ID
This command reports the device id.
This command is read only except through the front panel
.
Command Form
: DEVICE
DID
[Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
See
Type And Device IDs
(Null sent in text, Value returned)
DSPVER
– DSP Version
This command reports the version of the DSP code in the unit.
This command is read only.
Command Form
: DEVICE
DSPVER
<Value> [Time/Date]
Argument
Type
Size
Values
Units
Value
Unsigned Integer
4
0 for Host
1 – 8 for Satellite
9 for Telco
Time / Date
String
16
(Null to query in text)