20 Technical Services: 800-283-5936
FILTSEL
– Filter Select
This command turns on and off the filters.
Command Form
: DEVICE
FILTSEL
<Channel> <Group> <Node> [Value]
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
Group
Group
1
3, 5 (M, P)
Node
Unsigned Integer
1
Group 3
1 – 4
0xFF for all (*
text)
Group 5
1 – 15
0xFF for all (*
text)
Value
Unsigned Integer
1
0 = Off
1 = On
2 = Toggle
(Null to query in text)
FLOW
– Flow Control
This command selects/reports the flow control of the serial port on the unit. Hardware flow control is implemented
using DTR and DSR.
Command Form
: DEVICE
FLOW
[Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
0 = Off
1 = On
2 = Toggle
(Null to query in text)
FMP
– First Mic Priority Mode
This command selects/reports first Mic priority mode.
Command Form
: DEVICE
FMP
<Channel> [Value]
Argument Type
Size
Values
Units
Channel
Channel
1
See
Groups and Channels
Group
Group
1
4 (G)
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
FPGAVER
– FPGA Version
This command reports the version of the FPGA code in the unit.
This command is read only.
Command Form
: DEVICE
FPGAVER
[Value]
Argument Type
Size
Values
Units
Value
String
12
(Sent with a Null in text)