ClearFox®Control Unit CU-M
6
-
Overfill Float Switch: Optional.
Connected to the digital input terminal
DI1
inside the
controller (see chapter 5).
6.2
P
UMP
-SBR
Output functions can be selected via web pages.
-
Blower (+Valve) / Injection Aerator
: Connected to the electric socket of the
ClearFox®Control Unit CU-M
(+Out 5) / electric socket
.
-
Pumps / Valves
:
o
Filling: Direct submersible pump - Out 2; using the Sludge Pump
–
Sludge Pump
–
Out 4
o
Clearwater removal: Pump Out 3 / Valve Out 3 (+Blower)
o
Sludge return: Pump Out 4 / Valve Out 4 (+Blower)
-
BonFlash
alarm beacon
is connected to the terminals marked with
BF-C
(brown cable)
and
GND
(white cable), (see chapter 5).
-
Overfill Float Switch: Optional.
Connected to the digital input terminal
DI1
inside the
Sequetrol
® IoT
(see chapter 5).
6.3
O
NE
-T
ANK
SBR
Output functions can be selected via web pages.
-
Blower (+Valve) / Injection Aerator
: Connected to the electric socket of the
ClearFox®Control Unit CU-M
(+Out 5) / electric socket
.
-
Sludge return
: Pump Out 3 / Valve Out 3 (+Blower)
-
BonFlash
alarm beacon
is connected to the terminals marked with
BF-C
(brown cable)
and
GND
(white cable), (see chapter 5).
-
Overfill Float Switch: Optional.
Connected to the digital input terminal
DI1
inside the
(see chapter 5).
6.4
C
ONTINUOUS PLANTS
(MBBR,
F
IXED
-B
ED
,
…)
Output functions can be selected via web pages.
-
Blower (+Valve)
: Connected to the electric socket of the
ClearFox®Control Unit CU-M
(+Out 5)
-
Pumps / Valves
:
o
Filling: Submersible pump - Out 2 / Airlift
–
Out 2 (+Blower)
o
Clearwater removal: Pump Out 3 / Valve Out 3 (+Blower)
o
Sludge return: Pump Out 4 / Valve Out 4 (+Blower)
-
BonFlash
alarm beacon
is connected to the terminals marked with
BF-C
(brown cable)
and
GND
(white cable), (see chapter 5).
-
Overfill Float Switch: Optional.
Connected to the digital input terminal
DI1
inside the
(see chapter 5).
6.5
D
RIPPLING FILTER
(D:
T
ROPFKÖRPER
)
Work in progress…