Clearfield FieldSmart 96 Port PON Скачать руководство пользователя страница 18

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected] 

18

FieldSmart 96-Port PON FDH Cabinet

Installation Manual 

 _________________________________________________________

Manual 022684 REV A - Jan 2022

Standard Warranty

Clearfield warrants to the original purchaser of the Product sold hereunder is free from defects in material and workmanship under normal use and 

service, subject to exceptions stated herein. Product purchased is warranted as follows: Clearfield designed and branded Products are warranted for 

three (3) years: Products manufactured by Clearfield to customer prints and/or specifications are warranted for one (1) year; and any Product Clear

-

field acquires from or through a third-party manufacturer or distributor and resells to Customer as the original customer will carry the manufacturer’s 

pass-through warranty, if any. In all cases, the warranty period commences on the date of shipment to the original purchaser.

Warranty Claim Procedure

If any Product purchased from Clearfield is found defective under the above warranty, the following basic procedure must be followed:

1. 

Customer must contact Clearfield and obtain a Return Materials Authorization

2. 

Following authorization, the Customer ships the product-freight collect-to Clearfield’s manufacturing facility

3. 

Clearfield shall repair or replace the defective Product at its sole option and discretion, and return the repaired or replacement Product to Cus

-

tomer’s site, freight prepaid

Note: If the Product is not found to be defective by Clearfield, the product will be returned to the Customer and the customer billed for freight in both 

directions.

View our warranty policy here: 

https://www.seeclearfield.com/warranty.html

Limitations of Warranty

Correction of defects by repair or replacement, at the option of Clearfield Inc, shall constitute the exclusive sole remedy for a breach of this limited 

warranty. Clearfield shall not be liable under any circumstances for any special, consequential, incidental, punitive, or exemplary damages arising 

out of or in any way connected with the product or with agreement to sell product to buyer, including, but not limited to damages for lost profits, loss 

of use, or for any damages or sums paid by buyer to third parties. The foregoing limitation of liability shall apply whether the claim is based upon 

principles of contract, warranty, negligence or other tort, breach of statutory duty, principles of indemnity or contribution, the failure of any limited or 

exclusive remedy to achieve its essential purpose, or otherwise.

Clearfield will not be responsible for any labor or materials costs associated with installation or incorporation of Clearfield products at customer sites, 

including any costs of alteration, replacement or defective product, or any field repairs.

Other Limitations

Clearfield assumes no warranty liability regarding defects caused by:

1. 

Customer’s modification of Product, excepting installation activities described in Clearfield documentation

2. 

Customer re-packaging of Product for shipment to third parties or destinations other than those originally shipped to by Clearfield, or any de

-

fects suffered during shipping where the Product has been re-packaged

3. 

Customer’s installation or maintenance, excepting activities described in and performed in accordance with Clearfield documentation

4. 

Customer’s improper or negligent use or application of Product

5. 

Other causes external to the Product, including but not limited to accidents, catastrophe, acts of God, government action, war, riot, strikes, civil 

commotion, sovereign conduct, or the acts or conduct of any person or persons not party to or associated with Clearfield

6.  Environmental factors and weathering resulting in aging and damage not necessary or applicable to the function of the product

Содержание FieldSmart 96 Port PON

Страница 1: ...FieldSmart 96 Port PON FDH Cabinet Installation Manual _______________________________________________________ Manual 022684 Rev A Jan 2022...

Страница 2: ...______________________________________________ Manual 022684 REV A Jan 2022 Table of Contents Application 3 Technical Specifications 3 Mounting the Enclosure 4 Cable Installation and Splicing 6 Ground...

Страница 3: ...e Ports 4 Access Doors on both sides allow complete access to cabinet Splitter Capacity Up to 5 WaveSmart Ruggedized Splitters Security 4 Quarter Turn Latches with Pin in Hex Key Material Thickness 06...

Страница 4: ...he cabinet using the included hardware 3 Determine the top height of the cabinet Drill a 5 8 hole 9 inches below the anticipated height of the cabinet all the way through the pole Note Clearfield does...

Страница 5: ...Care should be taken to avoid over tightening and deforming the hoist plate Lock tight red should be used on nuts to prevent loosening of nuts Make sure the thread rod nut does not exceed the top bend...

Страница 6: ...the cabinet bulkhead as possible 1 Compression Fitting Grommet Cable Size Inches Small Black Grommet 0 3 0 4 Medium Black Grommet 0 41 0 5 Gray Grommet Comes Pre Installed 0 51 0 79 2 Select the compr...

Страница 7: ...he cable to fit through the internal sealing grommet Feed the cable through the sealcon Note Ensure the O ring on the underside of the sealcon is present before installation O Ring Secure the sealcon...

Страница 8: ...ng in the cassette Open the cable 8 Optionally group the buffer tubes to be spliced and fully insert them into one of the mesh sleeves snake skin enclosed in the ship along hardware This will help to...

Страница 9: ...e opened up and secured into the cassettes at the marks you made using a Left Exit configura tion The cassette will typically use 3 feet of fiber inside the splice tray Viewable here https www seeclea...

Страница 10: ...__________________________ Manual 022684 REV A Jan 2022 Grounding the Enclosure Clearfield recommends that all grounding installations follow the per local practice guidelines for each applica tion A...

Страница 11: ...Remove the wing nuts from the threaded rods at the top left of the front of the cabinet Install the splitter body into place on the threaded rods through the holes located in the corners of the split...

Страница 12: ...e the staging plate to the cabinet s bulkhead in the staging area by depressing the plungers of the push pull grommets on the staging plate 6 7 Thread velcro loops about 3 4 inches long through the br...

Страница 13: ...ng of the end face Learn the process of cleaning properly Note It is NOT recommended to use isopropyl alcohol to clean the end face Cleaning an SC LC Connector Cleaning the End Face Place one wiping p...

Страница 14: ...AND the Adapter Itself Lightly moisten the fiber optic swab 2 5mm 38542F or 1 25mm 38040 by spotting a small amount about 1 of Electro Wash PX or Electro Wash MX pen onto the QbE Hold the tip of the...

Страница 15: ...s with this or an equivalent type swab Cleans ALL MTP MPO connector end faces This swab also cleans the pins of the male connector Lightly spot a QbE 2 wipe on the platen with Electro Wash PX Fiber Op...

Страница 16: ...ins Cleaned like a single fiber connector using a cleaning platform The receptacles will be cleaned as long as you are using a combination clean ing process as recommended Again using a platen moisten...

Страница 17: ...separately or through the adapter Slightly engage probe by pulling back but do not allow to click Lightly spot a QbE 2 wipe on the platen with Elec tro Wash PX Fiber Optic Cleaner this will help alle...

Страница 18: ...option of Clearfield Inc shall constitute the exclusive sole remedy for a breach of this limited warranty Clearfield shall not be liable under any circumstances for any special consequential incidenta...

Страница 19: ...ied Every effort has been made to keep the information contained in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the docum...

Отзывы: