![Clearfield Clearview Blue Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/clearfield/clearview-blue/clearview-blue_installation-manual_2621165032.webp)
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
32
Clearview Blue Cassette
Installation Manual
_________________________________________________________
Manual 019389 Rev E - July 2018
Route the first twelve fibers into the
right slack storage chamber of the
splice tray.
Bring the fibers into splicing area
from the right, routing down and
around the right splice sleeve
chip, and cut them to length at
the left splice sleeve chip, so that
they match them up with your first
twelve fibers from the incoming
buffer tube.
Remove the fibers from the tray
Fibers 1-12
Fibers 13-24
Trim Here
Trim Here
Repeat the process on the right side with the two sets of twelve fibers from the pre-loaded fiber pigtail.
9.
10.
11.
Route the second group of twelve
fibers into the right slack storage
chamber of the splice tray.
Bring the fibers into splicing area
from the right, routing to the right
splice sleeve chip and trim to
length.
Remove the fibers from the tray.
12.
13.
14.