![Clearfield Clearview Blue Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/clearfield/clearview-blue/clearview-blue_installation-manual_2621165015.webp)
15
Clearview Blue Cassette
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
Manual 019389 Rev E - July 2018
Open the bottom slack storage cover, and identify
which entrance port is to be used.
•
Entrances 1L and 1R are used for the right and left
hand sides of the FxHD frame, respectively.
•
Entrances 2L and 2R work well for the right and
left hand sides, respectively, of FxDS panels with
no rear protection.
•
Entrances 3L and 3R are used in some wallboxes
and for special needs.
•
Entrances 1L, 3L and 2R require the use of the
Right Rear Redirect in the splice tray, detailed on
page 27.
Note: A strain relief boot is shown in every location,
but the cassette will include only one.
Opening the lower slack storage door to 90 degrees
will allow you to lift the door away from the base.
2R
1R
1L
2L
3R
3L
Cable Entrance Method: Slack Storage
The Clearview Blue Cassette allows for roughly 8 feet of slack storage in its lower chamber. The pictures shown in this
section will mostly feature buffer tube as that is the most visible of the options. While ribbon can be stored in the slack
storage chamber, the use of furcation tubing up to the cassette entrance is required. Tight buffer cable will not be able to be
slack stored in the cassette due to the increased cable diameter.
1.
Loose Tube
Slide the included rubber strain relief boot onto the buffer
tube to be spliced as shown. Push the boot down the tube
and out of the way, it will be utilized later in the process.
2.