![Clearfield Clearview Blue Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/clearfield/clearview-blue/clearview-blue_installation-manual_2621165011.webp)
11
Clearview Blue Cassette
__________________________________________________________
Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
Manual 019389 Rev E - July 2018
Tight buffer cable will be secured into the cassette in a similar manner to loose tube fiber. Shown below is a “left exit”
configuration. Simply secure the tight buffer cable to the other side of the splice tray for a “right exit”.
Note: Standard exit/entrance is determined looking from the back of the cassette.
1.
Measure 30 inches back from the end of the tight
buffer cable and mark the cable with a permanent
marker.
Note: Due to the size of the cable, a strain relief
boot will not be used with tight buffer cable.
2.
Remove the outer jacket from the cable at the mark
you made by carefully cutting a ring around the
outside.
3.
Remove any extra material inside the cable until all that remains are the 900 micron tight buffer fibers.
4.
Insert a cable tie (or piece of wax string) into the
desired tie-down holes at the top of the cassette.
Tight Buffer